{"id":4346,"date":"2024-12-13T13:36:48","date_gmt":"2024-12-13T05:36:48","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4346"},"modified":"2026-07-14T15:27:06","modified_gmt":"2026-07-14T07:27:06","slug":"module-rsd-controller-rapid-shutdown-yrsd-p-plc","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/ar\/module-level-firefighter-safety-switch\/yro-rapid-shutdown-module-rsd-mounted-and-rooftop-solar-power-systems-dustproof","title":{"rendered":"\u0648\u062d\u062f\u0629 \u0625\u064a\u0642\u0627\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0633\u0631\u064a\u0639 YRO \u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0634\u0645\u0633\u064a\u0629 \u0627\u0644\u0645\u062b\u0628\u062a\u0629 \u0639\u0644\u0649 \u0627\u0644\u0633\u0637\u062d \u0648\u0645\u0636\u0627\u062f\u0629 \u0644\u0644\u063a\u0628\u0627\u0631"},"content":{"rendered":"<p><iframe src=\"https:\/\/www.youtube.com\/embed\/88M1JpT2W8k\" width=\"960\" height=\"500\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p>The 2017 National Electrical Code (NEC) Section 690.12 requires the module-level rapid shutdown of solar systems, all conductors within an array\u2019s 1-ft boundary have to be reduced to 80V or less within 30 seconds of rapid shutdown initiation.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>High Craftsmanship and Standards<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" style=\"height: 400px; width: 970px;\" title=\"YRO Rapid Shutdown Module Key Features\" src=\"\/wp-content\/uploads\/otherImg\/1-1008.jpg\" alt=\"Key features of YRO solar rapid shutdown module including IP68 protection, 25A support, UL94-V0 flame retardant, and universal inverter compatibility.\" width=\"970\" height=\"400\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>\u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p>\u064a\u0643\u062a\u0628<\/p>\n<\/td>\n<td>\n<p>YRSD-1P<\/p>\n<\/td>\n<td>\n<p>YRSD-2P<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Number of PV Inputs<\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Number of Modules Recommend<\/p>\n<\/td>\n<td>\n<p>1-2<\/p>\n<\/td>\n<td>\n<p>2-4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum Allowed Input Voltage<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>120V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum Allowed Input Current<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>18A \/ 25A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum Output Volt age<\/p>\n<\/td>\n<td>\n<p>120V<\/p>\n<\/td>\n<td>\n<p>240V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System Volt age<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1000V \/ 1500V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control Compliance<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>24VDC + 2 x 0.8mm2 Cable<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control Requirements<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>21.6V~26.4V at nomi. 27~36mA\/unit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u062d\u064a\u0637\u0629<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-30\u00b0C to +60\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protection Temperature<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>85\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IP Level<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&gt;IP68, NEMA 4X<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Fire-proof Level<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Flame retardant, UL94-V0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Humidity<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0%~90%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PV Connectors<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Connector (Customized)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Design Life Span<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>25 years<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Size<\/p>\n<\/td>\n<td>\n<p>155.8*73.7*30.2<\/p>\n<\/td>\n<td>\n<p>155.8*73.7*30.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u0648\u0632\u0646<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&lt; 200g (Excluding Cables)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, PV1+ Input<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, PV1- Input<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, PV2+ Input<\/p>\n<\/td>\n<td>\n<p>\/<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, PV2- Input<\/p>\n<\/td>\n<td>\n<p>\/<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, Power Out put<\/p>\n<\/td>\n<td>\n<p>1800 \u0645\u0644\u0645<\/p>\n<\/td>\n<td>\n<p>1800 \u0645\u0644\u0645<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, 24Vdc Control Cable<\/p>\n<\/td>\n<td>\n<p>1800 \u0645\u0644\u0645<\/p>\n<\/td>\n<td>\n<p>1800 \u0645\u0644\u0645<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>andard Comliance<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>NEC2017\/2020 (690.12); UL1741; UL3741; IEC\/EN62109; IEC\/EN61000<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>YRSD Modular level PLC type<\/strong><br \/>\nThe YRSD Modular level PLC type is designed to be installed at solar panel level and provides safety shutdown ofthe DC supply to ZERO vOLTS in case of emergency. Shutdown is initiated in 4 ways &#8211; Manual Operation, ACSupply Cut-Off or Temperature Rise Trigger sunspec lnverter as follows:<\/p>\n<p><img decoding=\"async\" class=\"alignnone\" style=\"height: 520px; width: 970px;\" title=\"4 Ways to Trigger YRO Rapid Shutdown\" src=\"\/wp-content\/uploads\/otherImg\/FaXkStFxk87KhBnE.jpg\" alt=\"Diagram showing four emergency trigger methods for YRO solar rapid shutdown device: Temperature, AC Cut-Off, Manual Switch, and SunSpec Command.\" width=\"970\" height=\"520\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone\" style=\"height: 450px; width: 970px;\" title=\"YRO RSD Safety Approvals &amp; UL Certifications\" src=\"\/wp-content\/uploads\/otherImg\/iW3CimHhdPtPSQcn.jpg\" alt=\"UL1741 PVRSE and UL3741 PVRSS certified YRO rapid shutdown device for the North American solar market.\" width=\"970\" height=\"450\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>YRSD-1P<\/strong><br \/>\nwhen the open-circuit voltage of PV panel is below 120V.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" style=\"height: 722px; width: 970px;\" title=\"YRSD-1P System Wiring &amp; NEC Compliance Diagram\" src=\"\/wp-content\/uploads\/otherImg\/jWJTDWzYncENGbbi.jpg\" alt=\"Wiring diagram of YRO YRSD-1P rapid shutdown modules with SunSpec inverter for NEC 2017 and 2020 compliance.\" width=\"970\" height=\"722\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>YRSD-2P<\/strong><br \/>\nwhen the open-circuit voltage of Pv panel is below 120v.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" style=\"height: 611px; width: 970px;\" title=\"YRSD-2P Dual-Panel Wiring Diagram\" src=\"\/wp-content\/uploads\/otherImg\/BCC4xiBMMjjSPjbH.jpg\" alt=\"YRSD-2P system schematic showing odd-number solar panel configuration and SunSpec compatibility.\" width=\"970\" height=\"611\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The 2017 National Electrical Code (NEC) Section 690.12 requires the module-level rapid shutdown of solar systems, all conductors within an array\u2019s 1-ft boundary have to be reduced to 80V or less within 30 seconds of rapid shutdown initiation. &nbsp; High Craftsmanship and Standards &nbsp; Technical Data Type YRSD-1P YRSD-2P Number of PV Inputs 1 2 [&hellip;]<\/p>\n","protected":false},"featured_media":1859,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[52,54],"product_filter":[],"class_list":["post-4346","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-rapid-shutdown-device","product_category-module-level-firefighter-safety-switch"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/product\/4346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/product\/4346\/revisions"}],"predecessor-version":[{"id":5924,"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/product\/4346\/revisions\/5924"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/media\/1859"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/media?parent=4346"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/product_category?post=4346"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/ar\/wp-json\/wp\/v2\/product_filter?post=4346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}