{"id":4331,"date":"2024-12-13T13:36:47","date_gmt":"2024-12-13T05:36:47","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4331"},"modified":"2025-05-20T15:59:26","modified_gmt":"2025-05-20T07:59:26","slug":"dc-power-isolator-switch-yrds1el-n32-4","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/de\/isolator-switch\/dc-power-isolator-switch-yrds1el-n32-4","title":{"rendered":"DC-Leistungstrennschalter YRDS1EL-N32-4"},"content":{"rendered":"<p><iframe allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\" frameborder=\"0\" height=\"500\" src=\"https:\/\/www.youtube.com\/embed\/SwyNctSdlPo\" width=\"960\"><\/iframe><\/p>\n<p>Trennschalter der YRDS1-Serie eignen sich zum Isolieren von Leitungen in Hochspannungs-Gleichstrom-\u00dcbertragungs- und -Verteilungssystemen, beispielsweise zum Abschalten von Hochspannungs-Gleichstrom zwischen Solarmodulen und Wechselrichtern.<br \/>\nIn der rauen Arbeitsumgebung bietet es eine sichere und zuverl\u00e4ssige Steuerung der Stromversorgung, hohe Sicherheit und kann bedenkenlos verwendet werden.<\/p>\n<p>\u00a0<\/p>\n<h5><strong>Anwendung:<\/strong><\/h5>\n<p>Der Trennschalter der Serie YRDS1 ist f\u00fcr ein Stromnetz mit einer Nennspannung von 1200 V Gleichstrom oder weniger und einem Nennstrom von 32 A oder weniger geeignet.<br \/>\nDas Produkt kann f\u00fcr seltenes Ein- und Ausschalten verwendet werden und kann gleichzeitig 1\u20132 MPPT-Leitungen trennen. Es eignet sich besonders zum Isolieren von Leitungen in HG\u00dc-\u00dcbertragungs- und -Verteilungssystemen, beispielsweise zum Abschalten des Hochspannungsgleichstroms zwischen Solarmodulen und Wechselrichtern.<\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"\/wp-content\/uploads\/otherImg\/4T.png\" \/><\/p>\n<h5><strong>Struktur:<\/strong><\/h5>\n<p>Bei schr\u00e4ger Installation kann ein IP66-Wasserdichtigkeitsgrad erreicht werden<br \/>\nUV-best\u00e4ndiges und flammhemmendes Vo-Material<br \/>\nKontaktversilberung, Silberschichtdicke entspricht den h\u00f6chsten Standards der Branche<br \/>\nLichtbogenzeit in 3 ms<br \/>\nKeine Polarit\u00e4t<br \/>\nIn der AUS-Position verriegelbar<br \/>\nAn der Unterseite des Isolators angebrachtes Entl\u00fcftungsventil<br \/>\nAS 60947.3:2018 und IEC 60947.1:2015 Standard<br \/>\n5 Jahre Garantie, Produktversicherung und R\u00fcckrufversicherung verf\u00fcgbar<br \/>\n\u00a0<\/p>\n<h5><strong>Technische Daten:<\/strong><\/h5>\n<p>Daten gem\u00e4\u00df IEC\/EN60947-3:2009 + A1 + A2, AS60947.3, Nutzungskategorie DC-PV1, DC-PV2<\/p>\n<table cellspacing=\"0\" style=\"border-collapse:collapse\">\n<tbody>\n<tr>\n<td colspan=\"3\"><strong>Hauptparameter<\/strong><\/td>\n<td><strong>YRDS1EL\/N32\/4<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Bemessungsisolationsspannung<\/td>\n<td>Ui<\/td>\n<td>V<\/td>\n<td>1500<\/td>\n<\/tr>\n<tr>\n<td>Bemessungsthermischer Strom<\/td>\n<td>Ith<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<\/tr>\n<tr>\n<td>Bemessungssto\u00dfspannungsfestigkeit<\/td>\n<td>Uimp<\/td>\n<td>V<\/td>\n<td>8000<\/td>\n<\/tr>\n<tr>\n<td>Bewertetes Kurzschlussausschaltverm\u00f6gen<\/td>\n<td>lcw<\/td>\n<td>A<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" style=\"text-align:left\"><strong>Maximale Kabelquerschnitte (inkl. Jumper)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Solider Standard<\/td>\n<td>\u00a0<\/td>\n<td>mm\u00b2<\/td>\n<td>45032<\/td>\n<\/tr>\n<tr>\n<td>Flexibel<\/td>\n<td>\u00a0<\/td>\n<td>mm\u00b2<\/td>\n<td>45026<\/td>\n<\/tr>\n<tr>\n<td>Flexibel (+mehradriges Kabelende)<\/td>\n<td>\u00a0<\/td>\n<td>mm\u00b2<\/td>\n<td>45026<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" style=\"text-align:left\"><strong>Drehmoment<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Anzugsdrehmoment Klemmenschrauben M4<\/td>\n<td>\u00a0<\/td>\n<td>Nm<\/td>\n<td>1.2-1.8<\/td>\n<\/tr>\n<tr>\n<td>Anzugsdrehmoment Geh\u00e4usemontage<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td rowspan=\"2\">1.5-2.0<\/td>\n<\/tr>\n<tr>\n<td>Schrauben ST4.2 (Edelstahl 304)<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>Anziehen der Drehmomentknopfschrauben M3<\/td>\n<td>\u00a0<\/td>\n<td>Nm<\/td>\n<td>0.5-0.7<\/td>\n<\/tr>\n<tr>\n<td>Drehmoment ein- oder ausschalten<\/td>\n<td>\u00a0<\/td>\n<td>Nm<\/td>\n<td>0.9-1.3<\/td>\n<\/tr>\n<tr>\n<td>Das Verkabelungsdrehmoment auf der Basis<\/td>\n<td>\u00a0<\/td>\n<td>Nm<\/td>\n<td>1.1-1.4<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" style=\"text-align:left\"><strong>Allgemeine Parameter<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Knopfpositionen<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>AUS bei 9 Stunden, EIN bei 12 Stunden, EIN bei 3 Stunden<\/td>\n<\/tr>\n<tr>\n<td>Mechanisches Leben<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>Anzahl der DC-Pole<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>2 oder 4 (6,8 optional)<\/td>\n<\/tr>\n<tr>\n<td>Betriebstemperatur<\/td>\n<td>\u00a0<\/td>\n<td>\u2103<\/td>\n<td>-40 bis +85<\/td>\n<\/tr>\n<tr>\n<td>Lagertemperatur<\/td>\n<td>\u00a0<\/td>\n<td>\u2103<\/td>\n<td>-40 bis +85<\/td>\n<\/tr>\n<tr>\n<td>Verschmutzungsgrad<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>\u00dcberspannungskategorie<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>III<\/td>\n<\/tr>\n<tr>\n<td>IP-Schutzart<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>IP66<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<h5><strong>Technische Daten:<\/strong><\/h5>\n<p>Daten gem\u00e4\u00df IEC\/EN60947-3 2009+A1+A2. AS60947.3, Nutzungskategorie DC-PV1, DC-PV2<\/p>\n<table cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\">\n<p><strong>300V<\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p><strong>600V<\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p><strong>800V<\/strong><\/p>\n<\/td>\n<td colspan=\"2\">\n<p><strong>1000V<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Pole<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Anzahl der Saiten<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Teilenummer<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PV1<\/p>\n<\/td>\n<td>\n<p>PV2<\/p>\n<\/td>\n<td>\n<p>PV1<\/p>\n<\/td>\n<td>\n<p>PV2<\/p>\n<\/td>\n<td>\n<p>PV1<\/p>\n<\/td>\n<td>\n<p>PV2<\/p>\n<\/td>\n<td>\n<p>PV1<\/p>\n<\/td>\n<td>\n<p>PV2<\/p>\n<\/td>\n<td>\n<p>\u00a0<\/p>\n<\/td>\n<td>\n<p>\u00a0<\/p>\n<\/td>\n<td>\n<p>\u00a0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<td>\n<p>9<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>YRDS1 EL(DB)\/N32-2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<td>\n<p>9<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>YRDS1EL(DB)\/N32-4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>YRDS1EL(DB)\/N32-4S<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>YRDS1EL(DB)\/N32-4B<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>YRDS1EL(DB)\/N32-4T<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<h5><strong>Schaltkonfigurationen:<\/strong><\/h5>\n<p><strong><img decoding=\"async\" alt=\"\" src=\"\/wp-content\/uploads\/otherImg\/3-1123.jpg\" \/><\/strong><\/p>\n<p>\u00a0<\/p>\n<h5><strong>Daten gem\u00e4\u00df AS60947-3:2018<\/strong><\/h5>\n<table cellspacing=\"0\" style=\"border-collapse:collapse\">\n<tbody>\n<tr>\n<td colspan=\"1\" style=\"text-align:left\">Hauptkontakte<\/td>\n<td>\u00a0<\/td>\n<td>Typ<\/td>\n<td>YRDS1EL(DB)\/N32<\/td>\n<td>Anhang B5<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:left\">Bemessungsthermischer Strom<\/td>\n<td>Ithe<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<td>\\<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:left\">Bemessungsisolationsspannung<\/td>\n<td>Ui<\/td>\n<td>V<\/td>\n<td>1000<\/td>\n<td>\\<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:left\">Abstand der Kontakte (pro Pol)<\/td>\n<td>\u00a0<\/td>\n<td>mm<\/td>\n<td>8<\/td>\n<td>5x<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:left\">Bemessungsbetriebsstrom le (DC-PV2)<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>Operationen<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" style=\"text-align:left\">\n<p>1 Pol<br \/>\n\u00a0\u00a0\u00a01\u00a0<\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"\/wp-content\/uploads\/otherImg\/1-1339.png\" style=\"height:41px;width:48px\" \/><\/p>\n<\/td>\n<td>300V<\/td>\n<td>A<\/td>\n<td>25<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>400V<\/td>\n<td>A<\/td>\n<td>10<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>500V<\/td>\n<td>A<\/td>\n<td>8<\/td>\n<td>32<\/td>\n<\/tr>\n<tr>\n<td>600V<\/td>\n<td>A<\/td>\n<td>8<\/td>\n<td>32<\/td>\n<\/tr>\n<tr>\n<td>800V<\/td>\n<td>A<\/td>\n<td>3<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td>1000V<\/td>\n<td>A<\/td>\n<td>2<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" style=\"text-align:left\">\n<p>4-polig<br \/>\n\u00a0\u00a0\u00a02-polig in Reihe<br \/>\n\u00a0\u00a0\u00a04<\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"\/wp-content\/uploads\/otherImg\/2.png\" style=\"height:37px;width:86px\" \/><\/p>\n<\/td>\n<td>500V<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<td>128<\/td>\n<\/tr>\n<tr>\n<td>600V<\/td>\n<td>A<\/td>\n<td>13<\/td>\n<td>52<\/td>\n<\/tr>\n<tr>\n<td>700V<\/td>\n<td>A<\/td>\n<td>9<\/td>\n<td>36<\/td>\n<\/tr>\n<tr>\n<td>800V<\/td>\n<td>A<\/td>\n<td>9<\/td>\n<td>36<\/td>\n<\/tr>\n<tr>\n<td>900V<\/td>\n<td>A<\/td>\n<td>9<\/td>\n<td>36<\/td>\n<\/tr>\n<tr>\n<td>1000V<\/td>\n<td>A<\/td>\n<td>9<\/td>\n<td>36<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" style=\"text-align:left\">\n<p>2-polig<br \/>\n\u00a0\u00a0\u00a04-polig in Reihe<br \/>\n\u00a0\u00a0\u00a02H<\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"\/wp-content\/uploads\/otherImg\/5.png\" style=\"height:45px;width:85px\" \/><\/p>\n<\/td>\n<td>500V<\/td>\n<td>A<\/td>\n<td>40<\/td>\n<td>160<\/td>\n<\/tr>\n<tr>\n<td>600V<\/td>\n<td>A<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>700V<\/td>\n<td>A<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>800V<\/td>\n<td>A<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>900V<\/td>\n<td>A<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>1000V<\/td>\n<td>A<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" style=\"text-align:left\">\n<p>2-polig<br \/>\n\u00a0\u00a0\u00a04-polig in Reihe<br \/>\n\u00a0\u00a0\u00a04B<\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"\/wp-content\/uploads\/otherImg\/6.png\" style=\"height:39px;width:155px\" \/><\/p>\n<\/td>\n<td>500V<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<td>128<\/td>\n<\/tr>\n<tr>\n<td>600V<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<td>128<\/td>\n<\/tr>\n<tr>\n<td>700V<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<td>128<\/td>\n<\/tr>\n<tr>\n<td>800V<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<td>128<\/td>\n<\/tr>\n<tr>\n<td>900V<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<td>128<\/td>\n<\/tr>\n<tr>\n<td>1000V<\/td>\n<td>A<\/td>\n<td>32<\/td>\n<td>128<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>YRDS1 series isolator switches are suitable for isolating lines in high-voltage direct current transmission and distribution systems, such as cutting off high-voltage direct current between solar panels and inverters. In the harsh working environment, it provides safe and reliable control of the power supply, high safety, and can be used with confidence. \u00a0 Application: YRDS1 [&hellip;]<\/p>\n","protected":false},"featured_media":1803,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[70],"product_filter":[],"class_list":["post-4331","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-isolator-switch"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/product\/4331","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/product\/4331\/revisions"}],"predecessor-version":[{"id":4519,"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/product\/4331\/revisions\/4519"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/media\/1803"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/media?parent=4331"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/product_category?post=4331"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/de\/wp-json\/wp\/v2\/product_filter?post=4331"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}