{"id":4344,"date":"2024-12-13T13:36:48","date_gmt":"2024-12-13T05:36:48","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4344"},"modified":"2026-07-14T13:37:54","modified_gmt":"2026-07-14T05:37:54","slug":"module-level-firefighter-safety-switches","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/es\/module-level-firefighter-safety-switch\/module-level-firefighter-safety-switches-solar-panel-emergency-shutdown-rsd-ip68-waterproof","title":{"rendered":"La seguridad del bombero del nivel del m\u00f3dulo cambia la prenda impermeable de RSD IP68 del cierre de emergencia del panel solar"},"content":{"rendered":"<p><iframe src=\"https:\/\/www.youtube.com\/embed\/88M1JpT2W8k\" width=\"960\" height=\"500\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p>YRO Rapid Shutdown is a DC-breaking device used in photovoltaic system, it can limit the electric range and even DC voltage. To guarantee the safe of firefighters in the process of fire fighting and rescue of facilities installed with photovoltaic power generation system, and has no risk of electric shock.<\/p>\n<p><strong>High Craftsmanship and Standards<\/strong><\/p>\n<p><strong><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" style=\"height: 400px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/1-1144.jpg\" alt=\"YRO module level rapid shutdown device features including IP68 waterproof protection, UL94-V0 flame retardant rating, 25A current support, 85\u00b0C over-temperature protection and 25-year lifespan\" width=\"970\" height=\"400\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Datos t\u00e9cnicos<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p>Tipo<\/p>\n<\/td>\n<td>\n<p>YRSD-1P<\/p>\n<\/td>\n<td>\n<p>YRSD-2P<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Number of PV Inputs<\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Number of Modules Recommend<\/p>\n<\/td>\n<td>\n<p>1-2<\/p>\n<\/td>\n<td>\n<p>2-4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum Allowed Input Voltage<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>120V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum Allowed Input Current<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>18A \/ 25A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum Output Volt age<\/p>\n<\/td>\n<td>\n<p>120V<\/p>\n<\/td>\n<td>\n<p>240V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System Volt age<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1000V \/ 1500V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control Compliance<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>24VDC + 2 x 0.8mm2 Cable<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control Requirements<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>21.6V~26.4V at nomi. 27~36mA\/unit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Temperatura ambiente de funcionamiento<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-30\u00b0C to +60\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protection Temperature<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>85\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IP Level<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&gt;IP68, NEMA 4X<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Fire-proof Level<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Flame retardant, UL94-V0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Humidity<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0%~90%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PV Connectors<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Connector (Customized)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Design Life Span<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>25 years<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Size<\/p>\n<\/td>\n<td>\n<p>155.8*73.7*30.2<\/p>\n<\/td>\n<td>\n<p>155.8*73.7*30.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Peso<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&lt; 200g (Excluding Cables)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, PV1+ Input<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, PV1- Input<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, PV2+ Input<\/p>\n<\/td>\n<td>\n<p>\/<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, PV2- Input<\/p>\n<\/td>\n<td>\n<p>\/<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, Power Out put<\/p>\n<\/td>\n<td>\n<p>1800 mm<\/p>\n<\/td>\n<td>\n<p>1800 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cable Length, 24Vdc Control Cable<\/p>\n<\/td>\n<td>\n<p>1800 mm<\/p>\n<\/td>\n<td>\n<p>1800 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>andard Comliance<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>NEC2017\/2020 (690.12); UL1741; UL3741; IEC\/EN62109; IEC\/EN61000<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Resumen<\/strong><\/p>\n<p>The YRO Modular level RSD DC 24V Series Overview is designed to be installed at solar panel level and providessafety shutdown of the DC supply to ZERO VOLTS in case of emergency.Shutdown is initiated in 3 ways -ManualOperation,AC Supply Cut-Off or Temperature Rise Trigger as follows:<\/p>\n<p><img decoding=\"async\" class=\"alignnone\" style=\"height: 660px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/2-1147.jpg\" alt=\"YRO solar rapid shutdown device emergency shutdown methods including temperature rise trigger, AC power cut-off and manual emergency switch operation\" width=\"970\" height=\"660\" \/><\/p>\n<p><img decoding=\"async\" style=\"height: 670px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/3.jpg\" alt=\"\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>YRSD-1P 1-to-1 wiring<\/strong><br \/>\n<img decoding=\"async\" style=\"height: 670px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/4.jpg\" alt=\"\" \/><\/p>\n<p>Not: For NEC 2017 \/2010 compliance PV panels should be &lt;40v for 2-to-1 wiringand &gt; =40v for 1-to-1 wiring (For YRSD -1P)<br \/>\n\u00a0<\/p>\n<p><strong>YRSD-2P 2-to-1 wiring<\/strong><br \/>\n<img decoding=\"async\" style=\"height: 370px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/5.jpg\" alt=\"\" \/><\/p>\n<p><strong>YRSD-1P\/2P Series<\/strong><\/p>\n<p><strong><img decoding=\"async\" style=\"height: 370px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/6.jpg\" alt=\"\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dimensi\u00f3n<\/strong><\/p>\n<p><strong><img decoding=\"async\" style=\"height: 510px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/7-1337.jpg\" alt=\"\" \/><\/strong><\/p>\n<p><strong>Technical Specification<\/strong><\/p>\n<table cellspacing=\"0\">\n<tbody>\n<tr>\n<td>\n<p>Modelo<\/p>\n<\/td>\n<td>\n<p>YRSD-CB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating AC Voltage Range<\/p>\n<\/td>\n<td>\n<p>100V-240V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nominal Frequency<\/p>\n<\/td>\n<td>\n<p>50\/60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output Voltage<\/p>\n<\/td>\n<td>\n<p>24V DC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output Current\/Power<\/p>\n<\/td>\n<td>\n<p>2.2A\/50W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>24Vdc Control Cable Size<\/p>\n<\/td>\n<td>\n<p>0.823 mm2\/18 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>24Vdc Control Cable Length<br \/>\n\u00a0\u00a0\u00a0With Standard Connectors<\/td>\n<td>\n<p>20 m \/ 30 m \/100 m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Spare Terminal Connectors<\/p>\n<\/td>\n<td>\n<p>S\u00ed<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum YRSD-1P<\/p>\n<\/td>\n<td>\n<p>60 Units<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum YRSD-2P<\/p>\n<\/td>\n<td>\n<p>30 Units<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Dimensions (mm)<\/p>\n<\/td>\n<td>\n<p>250*210*210<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Lockable<\/p>\n<\/td>\n<td>\n<p>Optional (IP54)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rango de temperatura de funcionamiento<\/p>\n<\/td>\n<td>\n<p>-30\u00b0C~+70\u00b0C(50\u00b0C No degradation)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protection Class<\/p>\n<\/td>\n<td>\n<p>IP65<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Montaje<\/p>\n<\/td>\n<td>\n<p>Wall Mounted<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Maximum Distance<br \/>\n\u00a0\u00a0\u00a0(Last RSD to Controller Box)<\/td>\n<td>\n<p>200m<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Parallel connection of multiple control boxes<\/strong><\/p>\n<p><strong><img decoding=\"async\" style=\"height: 560px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/8.jpg\" alt=\"\" \/><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>YRO Rapid Shutdown is a DC-breaking device used in photovoltaic system, it can limit the electric range and even DC voltage. To guarantee the safe of firefighters in the process of fire fighting and rescue of facilities installed with photovoltaic power generation system, and has no risk of electric shock. High Craftsmanship and Standards &nbsp; [&hellip;]<\/p>\n","protected":false},"featured_media":1860,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[52,54],"product_filter":[],"class_list":["post-4344","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-rapid-shutdown-device","product_category-module-level-firefighter-safety-switch"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product\/4344","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":6,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product\/4344\/revisions"}],"predecessor-version":[{"id":5920,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product\/4344\/revisions\/5920"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/media\/1860"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/media?parent=4344"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product_category?post=4344"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product_filter?post=4344"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}