{"id":4393,"date":"2024-12-13T13:37:11","date_gmt":"2024-12-13T05:37:11","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4393"},"modified":"2026-07-13T16:02:21","modified_gmt":"2026-07-13T08:02:21","slug":"solar-rapid-shutdown-system-yrsd-4a","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/es\/string-level-rapid-shutdown\/rapid-shutdown-solar-quality-solar-fire-safety-solutions-with-ce","title":{"rendered":"Apagado r\u00e1pido Soluciones solares de seguridad contra incendios de calidad solar con CE"},"content":{"rendered":"<p><iframe src=\"https:\/\/www.youtube.com\/embed\/Vubp2dyTTIs?si=nCdiflAduwzKPT9R\" width=\"960\" height=\"500\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Why Choose YRO WiFi Rapid Shutdown?<\/strong><\/p>\n<p>1. WiFi RSD connects to mobile devices via wireless networks, enabling users to remotely control the power equipment switches. With an active network connection, users can monitor and manage devices in real time without needing to be physically present on-site. \u00a0<\/p>\n<p>2. Equipped with real-time data monitoring capabilities, WiFi RSD collects and reports critical device metrics such as current, voltage, and temperature, ensuring precise tracking of operational status. \u00a0<\/p>\n<p>3. WiFi RSD features intelligent automation, capable of executing shutdown operations automatically based on preset conditions, such as overload or overheating, enhancing safety and reliability. \u00a0<\/p>\n<p>4. With versatile applications, WiFi RSD is widely used across industries, including photovoltaics, smart homes, telecommunications, and agriculture. \u00a0<\/p>\n<p>&nbsp;<\/p>\n<p><strong>About Rapid Shutdown<\/strong><br \/>\n1.1 Intended Use of the Rapid Shutdown<br \/>\nEl Rapid Shutdown ha sido especialmente desarrollado como dispositivo de seguridad para instalaciones fotovoltaicas de corriente continua (DC). El seccionador CC se utiliza para desconectar los strings conectados de la instalaci\u00f3n en caso de una situaci\u00f3n de emergencia.<br \/>\nSuch an emergency situation could be in case of fifire.<br \/>\n1.2 Location of the Rapid Shutdown<br \/>\nThe Rapid Shutdown needs to be placed as close to the solar panels as possible. Due to its enclosure, the switch is protected against external inflfluences like dust and moisture. The whole set-up is conformed to IP66 which makes it suitable for outdoor usage when needed.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Shutdown\u00a0Mode<\/strong><\/p>\n<p><strong><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" style=\"height: 380px; width: 970px;\" title=\"YRO Solar Rapid Shutdown Working Modes\" src=\"\/wp-content\/uploads\/otherImg\/Shutdown-Mode-2A.jpg\" alt=\"Four operation modes of YRO Solar Rapid Shutdown System: Automatic thermal, AC power, Manual emergency, and RS485 remote shutdown.\" width=\"970\" height=\"380\" \/><\/strong><\/p>\n<p><strong>Datos t\u00e9cnicos<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p>Main\u00a0Parameters<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>YRSD-1A\u00a0toYRSD-10A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>String voltages (Vdc)<\/p>\n<\/td>\n<td>\n<p>1000V<\/p>\n<\/td>\n<td>\n<p>1500V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>String current (A)<\/p>\n<\/td>\n<td>\n<p>40A<\/p>\n<\/td>\n<td>\n<p>26A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>N\u00famero de cuerdas<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1 to 10<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Switch wiring<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>2\/4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating voltage<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>100Vac-270Vac<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nominal voltage<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>230 Vca<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nominal current<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>30mera<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Start up (loading) current<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>promedio 100 mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Switch on action current<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>max 300mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Feedback contact<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>24Vdc-300mA max<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating temperature range<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-40\u00b0C-+70\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Max. operating temperature<\/p>\n<p>before automatic switch off<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>+70\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage temperature range<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-40\u00b0C-+85\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Grado de protecci\u00f3n<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>P66<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nivel de protecci\u00f3n<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Class lI<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Certi\ufb02cation<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Ce\u00f1udo<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DC Switch disconnect according to<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>EN 60947- 1&amp;3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Number of operations<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>10000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Number of operations under load(PV1)<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&gt; 1500<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" class=\"alignnone\" style=\"height: 400px; width: 970px;\" title=\"YRO Rapid Shutdown Outdoor Installation Guide\" src=\"\/wp-content\/uploads\/otherImg\/JTFcRB4eKxQQMnSt.jpg\" alt=\"Recommended outdoor mounting locations for YRO Solar Rapid Shutdown System protecting against sun, rain, and snow.\" width=\"970\" height=\"400\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Diagram<\/strong><\/p>\n<p><strong><img decoding=\"async\" class=\"alignnone\" style=\"height: 600px; width: 970px;\" title=\"YRO Solar Rapid Shutdown Wiring Diagram\" src=\"\/wp-content\/uploads\/otherImg\/KBGMYZDbGGTkPCxi.jpg\" alt=\"Wiring diagram of YRO Solar Rapid Shutdown Firefighter Safety Switch connecting PV arrays and inverter.\" width=\"970\" height=\"600\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dimensions of YRSD<\/strong><\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" style=\"height: 450px; width: 970px;\" title=\"YRO YRSD Series Dimensional Drawing\" src=\"\/wp-content\/uploads\/otherImg\/CenEcPp3fiaF5eX2.jpg\" alt=\"Dimensional drawing of YRO YRSD Solar Rapid Shutdown Firefighter Safety Switch for 1 to 10 strings.\" width=\"970\" height=\"450\" \/><\/strong><br \/>\n\u00a0<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp; Why Choose YRO WiFi Rapid Shutdown? 1. WiFi RSD connects to mobile devices via wireless networks, enabling users to remotely control the power equipment switches. With an active network connection, users can monitor and manage devices in real time without needing to be physically present on-site. \u00a0 2. Equipped with real-time data monitoring capabilities, [&hellip;]<\/p>\n","protected":false},"featured_media":1797,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[52,53],"product_filter":[],"class_list":["post-4393","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-rapid-shutdown-device","product_category-string-level-rapid-shutdown"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product\/4393","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product\/4393\/revisions"}],"predecessor-version":[{"id":5911,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product\/4393\/revisions\/5911"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/media\/1797"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/media?parent=4393"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product_category?post=4393"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/es\/wp-json\/wp\/v2\/product_filter?post=4393"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}