{"id":4399,"date":"2024-12-13T13:37:11","date_gmt":"2024-12-13T05:37:11","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4399"},"modified":"2025-08-11T13:29:08","modified_gmt":"2025-08-11T05:29:08","slug":"solar-electric-pv-t2-dc-surge-protective-device-yrsp-d2","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/fr\/dc-surge-protector\/solar-electric-pv-t2-dc-surge-protective-device-wholesale-price-20-40ka","title":{"rendered":"Prix \u200b\u200bde gros de dispositif de protection contre les surtensions solaire \u00e9lectrique PV T2 DC 20-40kA"},"content":{"rendered":"<p><iframe src=\"https:\/\/www.youtube.com\/embed\/8skFafkBSyA\" width=\"960\" height=\"500\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<h5><strong>Application:<\/strong><\/h5>\n<p>Dispositif de protection contre les surtensions YRSP-D2, prot\u00e8ge contre les surtensions d'\u00e9clairage dans le syst\u00e8me solaire (syst\u00e8me d'alimentation photovolta\u00efque). Ces unit\u00e9s doivent \u00eatre install\u00e9es en parall\u00e8le sur les r\u00e9seaux DC \u00e0 prot\u00e9ger et assurer la protection des modes communs et diff\u00e9rents. Son emplacement d'installation est recommand\u00e9 aux deux extr\u00e9mit\u00e9s de la ligne d'alimentation CC (c\u00f4t\u00e9 panneau solaire et c\u00f4t\u00e9 onduleur\/convertisseur), si le cheminement de la ligne est externe et long. MOV haute \u00e9nergie \u00e9quip\u00e9s de sectionneurs thermiques sp\u00e9cifiques et associ\u00e9s.indicateurs de d\u00e9faillance.<\/p>\n<p>&nbsp;<\/p>\n<h5><strong>Caract\u00e9ristiques:<\/strong><\/h5>\n<table style=\"border-collapse: collapse;height: 612px;width: 956px\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Parasurtenseur s\u00e9rie YRSP-D2<\/strong><\/td>\n<td colspan=\"5\"><strong>YRSP-D2<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"7\">Sp\u00e9cifique au PV DC (IEC 61643-31\/EN 61643-31\/EN50539-11)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">P\u00f4le<\/td>\n<td colspan=\"3\">2P<\/td>\n<td colspan=\"2\">3p<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">Param\u00e8tre \u00e9lectrique<\/td>\n<td colspan=\"5\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">Test classifi\u00e9<\/td>\n<td colspan=\"5\">II<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">UCPV (V CC)<\/td>\n<td>600<\/td>\n<td>800<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>1500<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">ln(8\/20)ps(kA)<\/td>\n<td colspan=\"5\">20<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">lmax(8\/20)ps (kA)<\/td>\n<td colspan=\"5\">40<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">Haut (kV)<\/td>\n<td>2.8<\/td>\n<td>3<\/td>\n<td>3.2<\/td>\n<td>3.5<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">Type de courbe<\/td>\n<td colspan=\"5\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">Fen\u00eatre d'indication<\/td>\n<td colspan=\"5\">\u221a<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">Module enfichable<\/td>\n<td colspan=\"5\">\u221a<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">Contact de signalisation \u00e0 distance<\/td>\n<td colspan=\"5\">opinion<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" rowspan=\"3\">Contact de signalisation \u00e0 distance<\/td>\n<td>tension de fonctionnement maximale (V)<\/td>\n<td colspan=\"5\">250 CA\/30 V CC<\/td>\n<\/tr>\n<tr>\n<td>courant de fonctionnement maximum (A)1A(250V\/AC)<\/td>\n<td colspan=\"5\">1A (250 V\/CA)<\/td>\n<\/tr>\n<tr>\n<td>1A (30 V CC)<\/td>\n<td colspan=\"5\">1A (30 V\/CA)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">C\u00e2blage et installation<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" rowspan=\"2\">Capacit\u00e9 de c\u00e2blage (mm2)<\/td>\n<td>Fil dur<\/td>\n<td colspan=\"5\">4\u301c25<\/td>\n<\/tr>\n<tr>\n<td>Fil souple<\/td>\n<td colspan=\"5\">4\u301c16<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Longueur de d\u00e9nudage (mm)<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">10<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Vis de borne<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">M5<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" rowspan=\"3\">Couple (Nm)<\/td>\n<td>Circuit principal<\/td>\n<td colspan=\"5\">3.5<\/td>\n<\/tr>\n<tr>\n<td>Contact de signalisation \u00e0 distance<\/td>\n<td colspan=\"5\">0.25<\/td>\n<\/tr>\n<tr>\n<td>Tout le profil<\/td>\n<td colspan=\"5\">Ip40<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Classe de protection Port de connexion<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">Ip20<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Environnement d'installation<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">Pas de choc ni de vibration \u00e9vidents<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Altitude (m)<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">&lt;2000<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Temp\u00e9rature de fonctionnement<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">-73<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Humidit\u00e9 relative<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">30%\u301c90%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Comment installer<\/td>\n<td>&nbsp;<\/td>\n<td colspan=\"5\">Install\u00e9 avec un rail de montage en acier H35-7,5\/DIN35<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" rowspan=\"3\">Taille (mm)(LxHxL)<\/td>\n<td>(W)<\/td>\n<td colspan=\"3\">36<\/td>\n<td colspan=\"2\">54<\/td>\n<\/tr>\n<tr>\n<td>(H)<\/td>\n<td colspan=\"3\">92<\/td>\n<td colspan=\"2\">92<\/td>\n<\/tr>\n<tr>\n<td>(L)<\/td>\n<td colspan=\"3\">76<\/td>\n<td colspan=\"2\">76<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" colspan=\"2\">Poids (kg)<\/td>\n<td colspan=\"3\">0.24<\/td>\n<td colspan=\"2\">0.36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0Aucun cache m\u00e9tallique ne se trouve dans la zone des boutons de d\u00e9verrouillage du module, comme illustr\u00e9.<\/p>","protected":false},"excerpt":{"rendered":"<p>Application: YRSP-D2 surge protective device, protect against lighting surge voltages in solar system ( photovoltaic power supply system ). These units must be installed in parallel on the DC networks to be protected and provide common and different modes&#8217; protection. Its installed location is recommended at both ends of the DC power supply line (solar [&hellip;]<\/p>\n","protected":false},"featured_media":1865,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[65,66],"product_filter":[],"class_list":["post-4399","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-surge-protective-device","product_category-dc-surge-protector"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/product\/4399","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":2,"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/product\/4399\/revisions"}],"predecessor-version":[{"id":4907,"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/product\/4399\/revisions\/4907"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/media\/1865"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/media?parent=4399"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/product_category?post=4399"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/fr\/wp-json\/wp\/v2\/product_filter?post=4399"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}