{"id":4344,"date":"2024-12-13T13:36:48","date_gmt":"2024-12-13T05:36:48","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4344"},"modified":"2026-07-14T13:37:54","modified_gmt":"2026-07-14T05:37:54","slug":"module-level-firefighter-safety-switches","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/pt\/module-level-firefighter-safety-switch\/module-level-firefighter-safety-switches-solar-panel-emergency-shutdown-rsd-ip68-waterproof","title":{"rendered":"A seguran\u00e7a do sapador-bombeiro do n\u00edvel do m\u00f3dulo comuta a parada de emerg\u00eancia RSD IP68 do painel solar imperme\u00e1vel"},"content":{"rendered":"<p><iframe src=\"https:\/\/www.youtube.com\/embed\/88M1JpT2W8k\" width=\"960\" height=\"500\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p>YRO Rapid Shutdown \u00e9 um dispositivo de interrup\u00e7\u00e3o DC usado em sistema fotovoltaico, pode limitar a faixa el\u00e9trica e at\u00e9 mesmo a tens\u00e3o DC. Garantir a seguran\u00e7a dos bombeiros no processo de combate a inc\u00eandio e resgate de instala\u00e7\u00f5es instaladas com sistema de gera\u00e7\u00e3o de energia fotovoltaica, n\u00e3o havendo risco de choque el\u00e9trico.<\/p>\n<p><strong>Alto artesanato e padr\u00f5es<\/strong><\/p>\n<p><strong><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" style=\"height: 400px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/1-1144.jpg\" alt=\"YRO module level rapid shutdown device features including IP68 waterproof protection, UL94-V0 flame retardant rating, 25A current support, 85\u00b0C over-temperature protection and 25-year lifespan\" width=\"970\" height=\"400\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dados T\u00e9cnicos<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p>Tipo<\/p>\n<\/td>\n<td>\n<p>YRSD-1P<\/p>\n<\/td>\n<td>\n<p>YRSD-2P<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>N\u00famero de entradas fotovoltaicas<\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>N\u00famero de m\u00f3dulos recomendados<\/p>\n<\/td>\n<td>\n<p>1-2<\/p>\n<\/td>\n<td>\n<p>2-4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tens\u00e3o de entrada m\u00e1xima permitida<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>120V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Corrente de entrada m\u00e1xima permitida<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>18A\/25A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Idade m\u00e1xima da tens\u00e3o de sa\u00edda<\/p>\n<\/td>\n<td>\n<p>120V<\/p>\n<\/td>\n<td>\n<p>240 V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Idade da voltagem do sistema<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1000V\/1500V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conformidade de controle<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Cabo 24VCC + 2 x 0,8mm2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Requisitos de controle<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>21,6 V ~ 26,4 V no valor nominal. 27~36mA\/unidade<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Temperatura ambiente de opera\u00e7\u00e3o<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-30\u00b0C a +60\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Temperatura de prote\u00e7\u00e3o<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>85\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>N\u00edvel de IP<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&gt;IP68, NEMA 4X<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>N\u00edvel \u00e0 prova de fogo<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Retardador de chama, UL94-V0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Umidade<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0%~90%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conectores fotovoltaicos<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Conector (Personalizado)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vida \u00fatil do projeto<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>25 anos<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tamanho<\/p>\n<\/td>\n<td>\n<p>155.8*73.7*30.2<\/p>\n<\/td>\n<td>\n<p>155.8*73.7*30.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Peso<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&lt;200g (excluindo cabos)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comprimento do cabo, entrada PV1+<\/p>\n<\/td>\n<td>\n<p>300 mm<\/p>\n<\/td>\n<td>\n<p>300 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comprimento do cabo, entrada PV1<\/p>\n<\/td>\n<td>\n<p>300 mm<\/p>\n<\/td>\n<td>\n<p>300 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comprimento do cabo, entrada PV2+<\/p>\n<\/td>\n<td>\n<p>\/<\/p>\n<\/td>\n<td>\n<p>300 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comprimento do cabo, entrada PV2<\/p>\n<\/td>\n<td>\n<p>\/<\/p>\n<\/td>\n<td>\n<p>300 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comprimento do cabo, pot\u00eancia de sa\u00edda<\/p>\n<\/td>\n<td>\n<p>1800 mm<\/p>\n<\/td>\n<td>\n<p>1800 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comprimento do cabo, cabo de controle 24Vdc<\/p>\n<\/td>\n<td>\n<p>1800 mm<\/p>\n<\/td>\n<td>\n<p>1800 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>conformidade padr\u00e3o<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>NEC 2017\/2020 (690,12); UL1741; UL3741; CEI\/EN 62109; CEI\/EN 61000<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Resumo<\/strong><\/p>\n<p>A vis\u00e3o geral da s\u00e9rie RSD DC 24V de n\u00edvel modular YRO foi projetada para ser instalada no n\u00edvel do painel solar e fornece desligamento seguro da alimenta\u00e7\u00e3o CC para ZERO VOLTS em caso de emerg\u00eancia. O desligamento \u00e9 iniciado de 3 maneiras - Opera\u00e7\u00e3o manual, corte de alimenta\u00e7\u00e3o CA ou gatilho de aumento de temperatura da seguinte forma:<\/p>\n<p><img decoding=\"async\" class=\"alignnone\" style=\"height: 660px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/2-1147.jpg\" alt=\"YRO solar rapid shutdown device emergency shutdown methods including temperature rise trigger, AC power cut-off and manual emergency switch operation\" width=\"970\" height=\"660\" \/><\/p>\n<p><img decoding=\"async\" style=\"height: 670px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/3.jpg\" alt=\"\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Fia\u00e7\u00e3o 1 para 1 YRSD-1P<\/strong><br \/>\n<img decoding=\"async\" style=\"height: 670px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/4.jpg\" alt=\"\" \/><\/p>\n<p>Observa\u00e7\u00e3o: Para conformidade com NEC 2017\/2010, os pain\u00e9is fotovoltaicos devem ter  = 40 V para fia\u00e7\u00e3o 1 para 1 (para YRSD -1P)<br \/>\n\u00a0<\/p>\n<p><strong>Fia\u00e7\u00e3o 2 para 1 YRSD-2P<\/strong><br \/>\n<img decoding=\"async\" style=\"height: 370px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/5.jpg\" alt=\"\" \/><\/p>\n<p><strong>S\u00e9rie YRSD-1P\/2P<\/strong><\/p>\n<p><strong><img decoding=\"async\" style=\"height: 370px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/6.jpg\" alt=\"\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dimens\u00e3o<\/strong><\/p>\n<p><strong><img decoding=\"async\" style=\"height: 510px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/7-1337.jpg\" alt=\"\" \/><\/strong><\/p>\n<p><strong>Especifica\u00e7\u00e3o T\u00e9cnica<\/strong><\/p>\n<table cellspacing=\"0\">\n<tbody>\n<tr>\n<td>\n<p>Modelo<\/p>\n<\/td>\n<td>\n<p>YRSD-CB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Faixa de tens\u00e3o CA operacional<\/p>\n<\/td>\n<td>\n<p>100V-240V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Frequ\u00eancia Nominal<\/p>\n<\/td>\n<td>\n<p>50\/60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tens\u00e3o de sa\u00edda<\/p>\n<\/td>\n<td>\n<p>24V CC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Corrente\/pot\u00eancia de sa\u00edda<\/p>\n<\/td>\n<td>\n<p>2,2A\/50W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tamanho do cabo de controle 24Vcc<\/p>\n<\/td>\n<td>\n<p>0,823 mm2\/18 AWG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Comprimento do cabo de controle 24Vcc<br \/>\n\u00a0\u00a0\u00a0Com conectores padr\u00e3o<\/td>\n<td>\n<p>20m \/ 30m \/100m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conectores de terminal sobressalentes<\/p>\n<\/td>\n<td>\n<p>Sim<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M\u00e1ximo YRSD-1P<\/p>\n<\/td>\n<td>\n<p>60 unidades<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M\u00e1ximo YRSD-2P<\/p>\n<\/td>\n<td>\n<p>30 unidades<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Dimens\u00f5es (mm)<\/p>\n<\/td>\n<td>\n<p>250*210*210<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bloque\u00e1vel<\/p>\n<\/td>\n<td>\n<p>Opcional (IP54)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Faixa de temperatura operacional<\/p>\n<\/td>\n<td>\n<p>-30\u00b0C~+70\u00b0C(50\u00b0C Sem degrada\u00e7\u00e3o)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Classe de Prote\u00e7\u00e3o<\/p>\n<\/td>\n<td>\n<p>IP65<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Montagem<\/p>\n<\/td>\n<td>\n<p>Montado na parede<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Dist\u00e2ncia M\u00e1xima<br \/>\n\u00a0\u00a0\u00a0(\u00daltimo RSD para a caixa do controlador)<\/td>\n<td>\n<p>200m<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Conex\u00e3o paralela de m\u00faltiplas caixas de controle<\/strong><\/p>\n<p><strong><img decoding=\"async\" style=\"height: 560px; width: 970px;\" src=\"\/wp-content\/uploads\/otherImg\/8.jpg\" alt=\"\" \/><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>YRO Rapid Shutdown is a DC-breaking device used in photovoltaic system, it can limit the electric range and even DC voltage. To guarantee the safe of firefighters in the process of fire fighting and rescue of facilities installed with photovoltaic power generation system, and has no risk of electric shock. High Craftsmanship and Standards &nbsp; [&hellip;]<\/p>\n","protected":false},"featured_media":1860,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[52,54],"product_filter":[],"class_list":["post-4344","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-rapid-shutdown-device","product_category-module-level-firefighter-safety-switch"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product\/4344","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":6,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product\/4344\/revisions"}],"predecessor-version":[{"id":5920,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product\/4344\/revisions\/5920"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/media\/1860"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/media?parent=4344"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product_category?post=4344"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product_filter?post=4344"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}