{"id":4347,"date":"2024-12-13T13:36:48","date_gmt":"2024-12-13T05:36:48","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4347"},"modified":"2026-07-13T13:51:26","modified_gmt":"2026-07-13T05:51:26","slug":"solar-module-level-rapid-shutdown-yrsd-p","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/pt\/module-level-firefighter-safety-switch\/module-rapid-shutdown-rsd-with-ul-mark-for-enhanced-fire-protection-bulk-orders-from-trusted-factories","title":{"rendered":"M\u00f3dulo RSD de desligamento r\u00e1pido com marca UL para pedidos em massa aprimorados de prote\u00e7\u00e3o contra inc\u00eandio de f\u00e1bricas confi\u00e1veis"},"content":{"rendered":"<p>YRSD-1P \/ 2P \u00e9 um dispositivo de desligamento r\u00e1pido em n\u00edvel de m\u00f3dulo que oferece seguran\u00e7a contra inc\u00eandio para telhados e edif\u00edcios solares, permanece o per\u00edodo de fun\u00e7\u00e3o de desligamento r\u00e1pido durante toda a vida \u00fatil do sistema solar fotovoltaico.<br \/>\nO interruptor do bot\u00e3o de emerg\u00eancia \u00e9 necess\u00e1rio para iniciar a opera\u00e7\u00e3o de desligamento r\u00e1pido, como local de acionamento no solo e de f\u00e1cil acesso.<\/p>\n<p><strong>O cabo de comunica\u00e7\u00e3o no dispositivo de desligamento r\u00e1pido deve ser conectado em s\u00e9rie e conectado ao interruptor de bot\u00e3o.<\/strong><\/p>\n<p>\u25cf Desligamento r\u00e1pido em n\u00edvel de m\u00f3dulo<\/p>\n<p>\u25cf Desligamento manual por bot\u00e3o<\/p>\n<p>\u25cf Desligamento autom\u00e1tico em caso de perda de energia CA<\/p>\n<p>\u25cf Desligamento autom\u00e1tico por excesso de temperatura<\/p>\n<p>\u25cf Compat\u00edvel com a maioria dos inversores e pain\u00e9is de string<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dados T\u00e9cnicos<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Modelo n\u00e3o.<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>YRSD-1P\/2P<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Tens\u00e3o m\u00e1xima de entrada<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>Painel \u00fanico de 120 V ou 60 V por painel (dois pain\u00e9is em s\u00e9rie)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Corrente m\u00e1xima de entrada<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>18A<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>25a<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Pot\u00eancia M\u00e1xima<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>2160W no total<\/p>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<p>3000W no total<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Cabos de entrada e sa\u00edda fotovoltaica<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>Cabos + conectores de 4,0 mm\u00b2 (12AWG)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Comprimento do cabo de entrada fotovoltaica<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>180 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Comprimento do cabo de sa\u00edda fotovoltaica<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>1800 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Prote\u00e7\u00e3o IP<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>IP68<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Peso<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>1000g<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Temperatura operacional<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>-40\u2103 a- +85\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Temperatura ambiente de opera\u00e7\u00e3o<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>-40\u2103 a- +55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Conformidade com padr\u00f5es<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>EN61646 EN 61000, EN 61215 IEC 60716 projecto C (resistente a NH3)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Conectores fotovoltaicos:<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>Conector Staubi (padr\u00e3o), conectores Jinko e QC para op\u00e7\u00e3o<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"1\">\n<p>Fonte de alimenta\u00e7\u00e3o DC para cada RSD<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Faixa de tens\u00e3o<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>14V-28V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Corrente M\u00e1xima<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>15mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Pot\u00eancia M\u00e1xima<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>0,2W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Cabos de alimenta\u00e7\u00e3o (cabo de sinal)<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>2\u00d70,823mm\u00b2 \uff0818AWG\uff09Cabos de sinal + conectores de sinal<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Comprimento dos cabos de alimenta\u00e7\u00e3o<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>1800 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Garantia<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>5 anos<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<p>Peso<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<p>750g<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" title=\"YRO Solar System Installation Overview\" src=\"\/wp-content\/uploads\/otherImg\/Solar Module Level Rapid Shutdown YRSD-P-1.jpg\" alt=\"3D installation diagram of YRO residential solar PV system showing rooftop RSDs, inverter, and control box.\" width=\"900\" height=\"812\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>O desligamento r\u00e1pido tem aplica\u00e7\u00f5es importantes em muitos campos. Aqui est\u00e3o alguns usos comuns:<\/strong><\/p>\n<p>\u25cfSeguran\u00e7a e emerg\u00eancias: Em emerg\u00eancias, como inc\u00eandios, vazamentos ou outros eventos perigosos, o fornecimento de energia precisa ser cortado rapidamente para garantir a seguran\u00e7a do pessoal. O sistema de desligamento r\u00e1pido pode cortar rapidamente o fornecimento de energia e evitar riscos potenciais de expans\u00e3o adicional.<\/p>\n<p>\u25cfManuten\u00e7\u00e3o e inspe\u00e7\u00e3o: Ao realizar manuten\u00e7\u00e3o, inspe\u00e7\u00e3o ou substitui\u00e7\u00e3o de equipamentos, o equipamento deve ser desligado primeiro para garantir a seguran\u00e7a do pessoal e evitar falhas el\u00e9tricas. O recurso de desligamento r\u00e1pido permite que a corrente seja desconectada rapidamente, permitindo que os operadores realizem trabalhos de manuten\u00e7\u00e3o com seguran\u00e7a.<\/p>\n<p>\u25cfEvitar danos ao equipamento: Sob certas circunst\u00e2ncias, como sobrecargas de circuito, curto-circuitos ou condi\u00e7\u00f5es anormais, o equipamento pode ser danificado por corrente ou tens\u00e3o excessiva. Ao desligar a energia rapidamente, voc\u00ea pode interromper rapidamente o fluxo de eletricidade em um circuito, reduzindo o risco de danos ao seu equipamento.<\/p>\n<p>\u25cfGerenciamento de energia: O desligamento r\u00e1pido tamb\u00e9m pode ser usado para gerenciamento de energia e medidas de economia de energia. Quando o dispositivo est\u00e1 ocioso ou n\u00e3o em uso, ele pode cortar a fonte de alimenta\u00e7\u00e3o atrav\u00e9s de um desligamento r\u00e1pido para evitar desperd\u00edcio de energia e consumo desnecess\u00e1rio de energia.<\/p>\n<p>\u25cfProte\u00e7\u00e3o do Circuito: O desligamento r\u00e1pido pode ser usado para proteger outros equipamentos ou componentes contra poss\u00edveis danos quando ocorre uma falha ou condi\u00e7\u00e3o anormal em um circuito. Ele corta a corrente rapidamente e evita que as falhas se espalhem por todo o circuito.<\/p>\n<p>&nbsp;<\/p>\n<p>Em suma, o desligamento r\u00e1pido tem um valor de aplica\u00e7\u00e3o importante e pode garantir a seguran\u00e7a do pessoal, a opera\u00e7\u00e3o normal do equipamento e o gerenciamento da economia de energia. Ele desempenha um papel fundamental em situa\u00e7\u00f5es de emerg\u00eancia e fornece fun\u00e7\u00f5es de controle de energia e prote\u00e7\u00e3o de circuito necess\u00e1rias em muitas aplica\u00e7\u00f5es pr\u00e1ticas.<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>YRSD-1P\/2P is a module level rapid shutdown device offers fire safety for solar rooftop and building ,remains the rapid shutdown function period the solar PV system whole working life. Emergency button switch is required to initiate the rapid shutdown operating, as a trigger place on the ground and easier to reach. The communication cable on [&hellip;]<\/p>\n","protected":false},"featured_media":1791,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[52,54],"product_filter":[],"class_list":["post-4347","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-rapid-shutdown-device","product_category-module-level-firefighter-safety-switch"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product\/4347","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product\/4347\/revisions"}],"predecessor-version":[{"id":5906,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product\/4347\/revisions\/5906"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/media\/1791"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/media?parent=4347"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product_category?post=4347"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/pt\/wp-json\/wp\/v2\/product_filter?post=4347"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}