{"id":4345,"date":"2024-12-13T13:36:48","date_gmt":"2024-12-13T05:36:48","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4345"},"modified":"2025-08-09T11:15:29","modified_gmt":"2025-08-09T03:15:29","slug":"module-level-quick-shutdown-device-yrsd-p","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/th\/module-level-firefighter-safety-switch\/rapid-shutdown-solar-suitable-for-scale-solar-energy-projects-and-roof-installations-120v","title":{"rendered":"\u0e1e\u0e25\u0e31\u0e07\u0e07\u0e32\u0e19\u0e41\u0e2a\u0e07\u0e2d\u0e32\u0e17\u0e34\u0e15\u0e22\u0e4c\u0e01\u0e32\u0e23\u0e1b\u0e34\u0e14\u0e23\u0e30\u0e1a\u0e1a\u0e2d\u0e22\u0e48\u0e32\u0e07\u0e23\u0e27\u0e14\u0e40\u0e23\u0e47\u0e27\u0e40\u0e2b\u0e21\u0e32\u0e30\u0e2a\u0e33\u0e2b\u0e23\u0e31\u0e1a\u0e42\u0e04\u0e23\u0e07\u0e01\u0e32\u0e23\u0e1e\u0e25\u0e31\u0e07\u0e07\u0e32\u0e19\u0e41\u0e2a\u0e07\u0e2d\u0e32\u0e17\u0e34\u0e15\u0e22\u0e4c\u0e02\u0e19\u0e32\u0e14\u0e43\u0e2b\u0e0d\u0e48\u0e41\u0e25\u0e30\u0e01\u0e32\u0e23\u0e15\u0e34\u0e14\u0e15\u0e31\u0e49\u0e07\u0e2b\u0e25\u0e31\u0e07\u0e04\u0e32 120V"},"content":{"rendered":"<p><iframe src=\"https:\/\/www.youtube.com\/embed\/88M1JpT2W8k\" width=\"960\" height=\"500\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p>Rapid Shutdown Control Box is a fast shut-off device developed according to NEC2020 regulations. It controls the shutdown of YRSD-P Series RSD, eliminates the high voltage threat of PV system modules. In emergency situations such as fire, protect the personal safety of rescuers and avoid electric shock accidents.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e08\u0e33\u0e40\u0e1e\u0e32\u0e30<\/strong><\/p>\n<p>3% ~ 25% optimization, retrieve power generation loss<br \/>\n\u0394 &lt; 10\u2103 Anti-Hotspot, more safe and durable<br \/>\nApplies to all types of modules, Optimization +Voltage Limiting +Anti-Hotspot<br \/>\nBased on power optimization chip, eliminate panel or cell level mismatch<br \/>\nSolve the current mismatch issues caused by shading \u00a0gradients, aging variations, temperature gradients, soiling gradients, etc<br \/>\nOptimize power generation, lower LCOE, improve solar system reliability, extend the service life of module<br \/>\nTUV Certification<\/p>\n<p>&nbsp;<\/p>\n<p><strong>\u0e1e\u0e32\u0e23\u0e32\u0e21\u0e34\u0e40\u0e15\u0e2d\u0e23\u0e4c<\/strong><\/p>\n<table style=\"border-collapse: collapse\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td><strong>\u0e23\u0e38\u0e48\u0e19\u0e2a\u0e34\u0e19\u0e04\u0e49\u0e32<\/strong><\/td>\n<td><strong>YHQ-460<\/strong><\/td>\n<td><strong>YHQ-600<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Maximum Input Power<\/td>\n<td>460W<\/td>\n<td>600W<\/td>\n<\/tr>\n<tr>\n<td>Operating Voltage Range<\/td>\n<td>9\uff5e55V<\/td>\n<td>3\uff5e70V<\/td>\n<\/tr>\n<tr>\n<td>MPPT Voltage Range<\/td>\n<td>13\uff5e50v<\/td>\n<td>8\uff5e70V<\/td>\n<\/tr>\n<tr>\n<td>\u0e01\u0e23\u0e30\u0e41\u0e2a\u0e44\u0e1f\u0e40\u0e02\u0e49\u0e32\u0e2a\u0e39\u0e07\u0e2a\u0e38\u0e14<\/td>\n<td>13A<\/td>\n<td>15A<\/td>\n<\/tr>\n<tr>\n<td>Over-current Protection<\/td>\n<td>16A<\/td>\n<td>18\u0e40\u0e2d<\/td>\n<\/tr>\n<tr>\n<td>Over-temperature Protection<\/td>\n<td>150\u2103<\/td>\n<td>160\u2103<\/td>\n<\/tr>\n<tr>\n<td>Maximum Output Current<\/td>\n<td>13A<\/td>\n<td>17A<\/td>\n<\/tr>\n<tr>\n<td>Output Voltage Limiting Threshold<\/td>\n<td>42V<\/td>\n<td>42V<\/td>\n<\/tr>\n<tr>\n<td>Total Maximum System Voltage<\/td>\n<td>1500V<\/td>\n<td>1500V<\/td>\n<\/tr>\n<tr>\n<td>72 Type Module String@1500V<\/td>\n<td>36Modules<\/td>\n<td>36Modules<\/td>\n<\/tr>\n<tr>\n<td>72 Type Module String@1100V<\/td>\n<td>26Modules<\/td>\n<td>26Modules<\/td>\n<\/tr>\n<tr>\n<td>72 Type Module String@1000V<\/td>\n<td>24Modules<\/td>\n<td>24Modules<\/td>\n<\/tr>\n<tr>\n<td>Peak Conversion Efficiency<\/td>\n<td>99.50%<\/td>\n<td>99.50%<\/td>\n<\/tr>\n<tr>\n<td>Power Consumption @5A<\/td>\n<td>0.9W<\/td>\n<td>0.9W<\/td>\n<\/tr>\n<tr>\n<td>Power Consumption @8A<\/td>\n<td>1.4W<\/td>\n<td>1.4W<\/td>\n<\/tr>\n<tr>\n<td>Power Consumption@12A<\/td>\n<td>2.9W<\/td>\n<td>2.9W<\/td>\n<\/tr>\n<tr>\n<td>Power Consumption@15A<\/td>\n<td>4.5W<\/td>\n<td>3.8W<\/td>\n<\/tr>\n<tr>\n<td>Power Consumption @20A<\/td>\n<td>7.2W<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td>Dimensions(L\u00d7W\u00d7H)<\/td>\n<td>105*105*20mm<\/td>\n<td>105*105*20mm<\/td>\n<\/tr>\n<tr>\n<td>\u0e19\u0e49\u0e33\u0e2b\u0e19\u0e31\u0e01<\/td>\n<td>500g<\/td>\n<td>500g<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\u0e40\u0e04\u0e40\u0e1a\u0e34\u0e25<\/td>\n<td>4.0mm2<\/td>\n<td>4.0mm2<\/td>\n<\/tr>\n<tr>\n<td>lnput Wire100 cm* 2Pcs<\/td>\n<td>lnput Wire50 cm* 2Pcs<\/td>\n<\/tr>\n<tr>\n<td>Output Wire70 cm*2Pcs<\/td>\n<td>Output Wire70 cm*2Pcs<\/td>\n<\/tr>\n<tr>\n<td>\u0e15\u0e31\u0e27\u0e40\u0e0a\u0e37\u0e48\u0e2d\u0e21\u0e15\u0e48\u0e2d<\/td>\n<td>Connector(Compatible)<\/td>\n<td>Connector(Compatible)<\/td>\n<\/tr>\n<tr>\n<td>\u0e0a\u0e48\u0e27\u0e07\u0e2d\u0e38\u0e13\u0e2b\u0e20\u0e39\u0e21\u0e34\u0e43\u0e19\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19<\/td>\n<td>\ufe6340\u2103\uff5e\ufe6265\u2103<\/td>\n<td>\ufe6340\u2103\uff5e\ufe6285\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u0e23\u0e30\u0e14\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e1b\u0e49\u0e2d\u0e07\u0e01\u0e31\u0e19<\/td>\n<td>lP68<\/td>\n<td>lP68<\/td>\n<\/tr>\n<tr>\n<td>Designed Life<\/td>\n<td>25 Years<\/td>\n<td>30 Years<\/td>\n<\/tr>\n<tr>\n<td>Quality Commitment<\/td>\n<td>12 Years<\/td>\n<td>12 Years<\/td>\n<\/tr>\n<tr>\n<td>Standard Features<\/td>\n<td>Optimization;Anti-Hotspot<\/td>\n<td>ptimization; Voltage Limiting; Anti-Hotspot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"4\"><strong>YHQ-460<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Module&#038;lnverter*<\/td>\n<td>Conventional Module<\/td>\n<td>Optimized Module<\/td>\n<td>Cost Reduction<\/td>\n<\/tr>\n<tr>\n<td>Maximum Module Qty\/String<\/td>\n<td>100oV\u00f753V=18pcs<\/td>\n<td>1000V\u00f742V = 24pcs<\/td>\n<td>Module Qty add 33%<\/td>\n<\/tr>\n<tr>\n<td>Power\/String<\/td>\n<td>18pcs\u00d7450W =8100W<\/td>\n<td>24pcs\u00d7450W= 10800W<\/td>\n<td>Power add 33%<\/td>\n<\/tr>\n<tr>\n<td>Tandem Inverter (2 strings)<\/td>\n<td>8100W\u00d72strings = 16.2kW<\/td>\n<td>10800w\u00d72strings = 21.6kW<\/td>\n<td>Cost \/Wp \u2193<\/td>\n<\/tr>\n<tr>\n<td>\u0e40\u0e04\u0e40\u0e1a\u0e34\u0e25<\/td>\n<td>\u0e2a\u0e32\u0e22\u0e14\u0e35\u0e0b\u0e35<\/td>\n<td>String Qty\/Labor Cost\/consumption\/Line Loss\u2193<\/td>\n<td>Cost \/Wp \u2193<\/td>\n<\/tr>\n<tr>\n<td>String Operating Voltage<\/td>\n<td>600V\u00ad700v<\/td>\n<td>800V\u00ad930V<\/td>\n<td>Higher System Efficiency<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table style=\"border-collapse: collapse\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"4\"><strong>YHQ-600<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Module&#038;lnverter*<\/td>\n<td>Conventional Module<\/td>\n<td>Optimized Module<\/td>\n<td>Cost Reduction<\/td>\n<\/tr>\n<tr>\n<td>Maximum Module Qty\/String<\/td>\n<td>100oV\u00f753V=20pcs<\/td>\n<td>1100V\u00f742V = 26pcs<\/td>\n<td>Module Qty add 33%<\/td>\n<\/tr>\n<tr>\n<td>Power\/String<\/td>\n<td>20pcs\u00d7370W =7400W<\/td>\n<td>26pcs\u00d7370W= 9620W<\/td>\n<td>Power add 30%<\/td>\n<\/tr>\n<tr>\n<td>Combiner Box (16 strings)<\/td>\n<td>7400W\u00d716strings = 118.4kW<\/td>\n<td>9620W\u00d716strings = 153.9kW<\/td>\n<td>Cost \/Wp \u2193<\/td>\n<\/tr>\n<tr>\n<td>Central Inverter (16 strings)<\/td>\n<td>118.4kW\u00d716strings =1894kW<\/td>\n<td>153.9KW\u00d716strings = 2463kW<\/td>\n<td>Cost \/Wp \u2193<\/td>\n<\/tr>\n<tr>\n<td>\u0e40\u0e04\u0e40\u0e1a\u0e34\u0e25<\/td>\n<td>\u0e2a\u0e32\u0e22\u0e14\u0e35\u0e0b\u0e35<\/td>\n<td>String Qty\/Labor Cost\/Line Loss\u2193<\/td>\n<td>Cost \/Wp \u2193<\/td>\n<\/tr>\n<tr>\n<td>String Operating Voltage<\/td>\n<td>750V\u00ad780v<\/td>\n<td>850V\u00ad900V<\/td>\n<td>Higher System Efficiency<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" src=\"\/wp-content\/uploads\/otherImg\/xYsmjrcj5s54cwfw.jpg\" alt=\"\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>\u0e42\u0e04\u0e49\u0e07<\/strong><\/p>\n<p><strong><img decoding=\"async\" style=\"height: 320px;width: 970px\" src=\"\/wp-content\/uploads\/otherImg\/fpd6wr4yBXtxFZEC.jpg\" alt=\"\" \/><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Rapid Shutdown Control Box is a fast shut-off device developed according to NEC2020 regulations. It controls the shutdown of YRSD-P Series RSD, eliminates the high voltage threat of PV system modules. In emergency situations such as fire, protect the personal safety of rescuers and avoid electric shock accidents. &nbsp; Specifications 3% ~ 25% optimization, retrieve [&hellip;]<\/p>\n","protected":false},"featured_media":3919,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[52,54],"product_filter":[],"class_list":["post-4345","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-rapid-shutdown-device","product_category-module-level-firefighter-safety-switch"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/product\/4345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":2,"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/product\/4345\/revisions"}],"predecessor-version":[{"id":4874,"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/product\/4345\/revisions\/4874"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/media\/3919"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/media?parent=4345"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/product_category?post=4345"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/th\/wp-json\/wp\/v2\/product_filter?post=4345"}],"curies":[{"name":"\u0e2b\u0e19\u0e49\u0e32","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}