{"id":5223,"date":"2025-11-18T14:56:57","date_gmt":"2025-11-18T06:56:57","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=blog&#038;p=5223"},"modified":"2025-11-18T14:56:57","modified_gmt":"2025-11-18T06:56:57","slug":"string-level-vs-module-level-rapid-shutdown-6-key-differences","status":"publish","type":"blog","link":"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences","title":{"rendered":"String-Level vs Module-Level Rapid Shutdown: 6 Key Differences"},"content":{"rendered":"<p>When you design or upgrade a solar project, you need a rapid shutdown solution that meets NEC 2017\/2020 safety codes while keeping installation costs under control. You are likely comparing <strong>string level rapid shutdown<\/strong> V\u00e0 <strong>module level rapid shutdown<\/strong> to decide which works best for your business. This guide gives you clear, buyer-focused answers.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_76 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">M\u1ee5c l\u1ee5c<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Chuy\u1ec3n \u0111\u1ed5i m\u1ee5c l\u1ee5c\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Chuy\u1ec3n \u0111\u1ed5i<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#What_Are_String-Level_and_Module-Level_Rapid_Shutdown\" >What Are String-Level and Module-Level Rapid Shutdown?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#String-Level_Rapid_Shutdown\" >String-Level Rapid Shutdown<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#Module-Level_Rapid_Shutdown\" >Module-Level Rapid Shutdown<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#6_Key_Differences_Between_String-Level_and_Module-Level_Rapid_Shutdown\" >6 Key Differences Between String-Level and Module-Level Rapid Shutdown<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#1_Safety_Performance\" >1. Safety Performance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#2_NEC_Compliance_Requirements\" >2. NEC Compliance Requirements<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#3_Installation_Complexity\" >3. Installation Complexity<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#4_Cost_Differences\" >4. Cost Differences<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#5_Troubleshooting_and_Maintenance\" >5. Troubleshooting and Maintenance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#6_Monitoring_and_System_Visibility\" >6. Monitoring and System Visibility<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#Comparison_Table_String-Level_vs_Module-Level_Rapid_Shutdown\" >Comparison Table: String-Level vs Module-Level Rapid Shutdown<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#Which_Solution_Should_You_Choose\" >Which Solution Should You Choose?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#Recommended_Rapid_Shutdown_Solution_from_YRO\" >Recommended Rapid Shutdown Solution from YRO<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#Conclusion\" >Ph\u1ea7n k\u1ebft lu\u1eadn<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#FAQs\" >FAQs<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#1_Do_all_rooftop_PV_systems_require_module-level_rapid_shutdown\" >1. Do all rooftop PV systems require module-level rapid shutdown?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#2_Is_module-level_rapid_shutdown_always_safer\" >2. Is module-level rapid shutdown always safer?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#3_Will_string-level_RSD_pass_inspections\" >3. Will string-level RSD pass inspections?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.yroele.com\/vi\/news\/string-level-vs-module-level-rapid-shutdown-6-key-differences\/#4_Does_YRO_offer_both_string_and_module-level_solutions\" >4. Does YRO offer both string and module-level solutions?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"What_Are_String-Level_and_Module-Level_Rapid_Shutdown\"><\/span><strong>What Are String-Level and Module-Level Rapid Shutdown?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"String-Level_Rapid_Shutdown\"><\/span><strong>String-Level Rapid Shutdown<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A system that shuts down DC voltage at the <a href=\"https:\/\/www.yroele.com\/vi\/string-level-rapid-shutdown\/rapid-shutdown-device-for-solar-pv-array-level-6-10-strings-600v-1500v\/?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\"><strong>string level<\/strong><\/a>, cutting power for the entire PV string when emergency shutdown is activated. It is simpler, more affordable, and suitable for many commercial systems.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Module-Level_Rapid_Shutdown\"><\/span><strong>Module-Level Rapid Shutdown<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A device installed on <strong>each PV module<\/strong> that brings module voltage below 30V within 30 seconds, meeting the strictest NEC requirements. It delivers maximum safety and panel-level isolation.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"6_Key_Differences_Between_String-Level_and_Module-Level_Rapid_Shutdown\"><\/span><strong>6 Key Differences Between String-Level and Module-Level Rapid Shutdown<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Below is a clear comparison so you can quickly understand which technology suits your project.<\/p>\n<p><a href=\"https:\/\/www.yroele.com\/vi\/rapid-shutdown-device\/\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-5225 size-full\" src=\"https:\/\/i1.wp.com\/www.yroele.com\/wp-content\/uploads\/2025\/11\/String-Level-vs-Module-Level-Rapid-Shutdown.png?quality=85&strip=all\" alt=\"String-Level vs Module-Level Rapid Shutdown\" width=\"1280\" height=\"720\" srcset=\"https:\/\/i1.wp.com\/www.yroele.com\/wp-content\/uploads\/2025\/11\/String-Level-vs-Module-Level-Rapid-Shutdown.png?quality=85&strip=all 1280w, https:\/\/i1.wp.com\/www.yroele.com\/wp-content\/uploads\/2025\/11\/String-Level-vs-Module-Level-Rapid-Shutdown-300x169.png?quality=85&strip=all 300w, https:\/\/i1.wp.com\/www.yroele.com\/wp-content\/uploads\/2025\/11\/String-Level-vs-Module-Level-Rapid-Shutdown-1024x576.png?quality=85&strip=all 1024w, https:\/\/i1.wp.com\/www.yroele.com\/wp-content\/uploads\/2025\/11\/String-Level-vs-Module-Level-Rapid-Shutdown-768x432.png?quality=85&strip=all 768w\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/><\/a><\/p>\n<h3><span class=\"ez-toc-section\" id=\"1_Safety_Performance\"><\/span><strong>1. Safety Performance<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong>String Level: <\/strong>Cuts power at the string boundary. Voltage between modules may still exist inside the array.<\/p>\n<p><strong>Module Level: <\/strong>Shuts down <strong>each module<\/strong>, providing the highest possible safety for firefighters and maintenance teams.<\/p>\n<p><strong>Example:<\/strong><br \/>\nA school rooftop project in Texas required sub-30V module-level shutdown due to strict local code enforcement. Only a <a href=\"https:\/\/www.yroele.com\/vi\/module-level-firefighter-safety-switch\/yro-rapid-shutdown-module-rsd-mounted-and-rooftop-solar-power-systems-dustproof\/?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\"><strong>module level rapid shutdown<\/strong><\/a> solution was accepted.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"2_NEC_Compliance_Requirements\"><\/span><strong>2. NEC Compliance Requirements<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong>NEC 2017:<\/strong> Often allows string-level solutions depending on layout.<\/p>\n<p><strong>NEC 2020:<\/strong> Strongly favors module-level shutdown in most rooftop scenarios.<\/p>\n<p>If your AHJ (Authority Having Jurisdiction) enforces NEC 2020 strictly, you may need module-level protection.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"3_Installation_Complexity\"><\/span><strong>3. Installation Complexity<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong>String-Level Rapid Shutdown:<\/strong><\/p>\n<p>Fewer devices \u2192 faster installation<\/p>\n<p>Lower wiring complexity<\/p>\n<p><strong>Module-Level Rapid Shutdown:<\/strong><\/p>\n<p>Requires one device per module<\/p>\n<p>More wiring, more labor time<\/p>\n<p><strong>Installer feedback example: <\/strong>A commercial EPC reported a <strong>30% faster installation time<\/strong> using string-level RSD in a 500 kW system because only a few devices were mounted near the combiner box.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"4_Cost_Differences\"><\/span><strong>4. Cost Differences<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong>String Level:<\/strong> Lower device cost + lower labor<\/p>\n<p><strong>Module Level:<\/strong> Higher cost due to per-module devices, but higher safety<\/p>\n<p>For large commercial rooftops (200 kW+), string level is often more cost-efficient unless local codes demand module-level.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"5_Troubleshooting_and_Maintenance\"><\/span><strong>5. Troubleshooting and Maintenance<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong>String Level:<\/strong><\/p>\n<p>Fewer components \u2192 easier troubleshooting<\/p>\n<p>Simple to replace<\/p>\n<p><strong>Module Level:<\/strong><\/p>\n<p>More devices mean more potential failure points<\/p>\n<p>Harder to access if mounted behind panels<\/p>\n<h3><span class=\"ez-toc-section\" id=\"6_Monitoring_and_System_Visibility\"><\/span><strong>6. Monitoring and System Visibility<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Some module-level systems integrate monitoring, allowing panel-level performance data.<br \/>\nString-level shutdown typically provides <strong>string-level<\/strong> visibility only.<\/p>\n<p>For EPCs managing long-term O&amp;M contracts, module-level monitoring can reduce diagnostic time.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Comparison_Table_String-Level_vs_Module-Level_Rapid_Shutdown\"><\/span><strong>Comparison Table: String-Level vs Module-Level Rapid Shutdown<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table>\n<thead>\n<tr>\n<th>T\u00ednh n\u0103ng<\/th>\n<th>String-Level Rapid Shutdown<\/th>\n<th>Module-Level Rapid Shutdown<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Safety Level<\/td>\n<td>Trung b\u00ecnh<\/td>\n<td>Highest<\/td>\n<\/tr>\n<tr>\n<td>NEC 2017 Compliance<\/td>\n<td>\u0110\u00fang<\/td>\n<td>\u0110\u00fang<\/td>\n<\/tr>\n<tr>\n<td>NEC 2020 Compliance<\/td>\n<td>Limited<\/td>\n<td>Fully compliant<\/td>\n<\/tr>\n<tr>\n<td>Installation Complexity<\/td>\n<td>Th\u1ea5p<\/td>\n<td>Cao<\/td>\n<\/tr>\n<tr>\n<td>Maintenance<\/td>\n<td>Easy<\/td>\n<td>Moderate\/Hard<\/td>\n<\/tr>\n<tr>\n<td>Cost<\/td>\n<td>Lower<\/td>\n<td>Higher<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"Which_Solution_Should_You_Choose\"><\/span><strong>Which Solution Should You Choose?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Choose String-Level Rapid Shutdown if you:<\/strong><\/p>\n<ul>\n<li>\n<p>Manage large commercial projects<\/p>\n<\/li>\n<li>\n<p>Want a cost-effective, low-complexity solution<\/p>\n<\/li>\n<li>\n<p>Are operating in regions where NEC 2017 is acceptable<\/p>\n<\/li>\n<\/ul>\n<p><strong>Choose Module-Level Rapid Shutdown if you:<\/strong><\/p>\n<ul>\n<li>\n<p>Must meet NEC 2020 module voltage requirements<\/p>\n<\/li>\n<li>\n<p>Install on schools, hospitals, or buildings with strict safety regulations<\/p>\n<\/li>\n<li>\n<p>Need highest-level firefighter protection<\/p>\n<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Recommended_Rapid_Shutdown_Solution_from_YRO\"><\/span><strong>Recommended Rapid Shutdown Solution from YRO<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>If you want a reliable, code-compliant shutdown solution, YRO offers advanced <strong>thi\u1ebft b\u1ecb t\u1eaft m\u00e1y nhanh<\/strong> designed for both string-level and module-level architectures.<\/p>\n<p>\ud83d\udd17 <strong>View product:<\/strong><br \/>\n<a href=\"https:\/\/www.yroele.com\/vi\/rapid-shutdown-device\/\" target=\"_blank\" rel=\"noopener\">https:\/\/www.yroele.com\/rapid-shutdown-device\/<\/a><\/p>\n<p>With proven performance in commercial and industrial PV systems worldwide, YRO RSD helps you simplify installation while enhancing on-site electrical safety.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span><strong>Ph\u1ea7n k\u1ebft lu\u1eadn<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When comparing <strong>string level rapid shutdown<\/strong> V\u00e0 <strong>module level rapid shutdown<\/strong>, you should focus on code compliance, installation cost, and safety needs. By understanding these six key differences, you can select the most suitable solution for your project. <a href=\"https:\/\/www.yroele.com\/vi\/\" target=\"_blank\" rel=\"noopener\"><strong>YRO<\/strong><\/a> provides dependable RSD products customized for professional solar installers and EPCs.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"FAQs\"><\/span><strong>FAQs<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"1_Do_all_rooftop_PV_systems_require_module-level_rapid_shutdown\"><\/span><strong>1. Do all rooftop PV systems require module-level rapid shutdown?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Not always. It depends on local enforcement of NEC 2017 or NEC 2020. Some areas accept string-level, while others require module-level.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"2_Is_module-level_rapid_shutdown_always_safer\"><\/span><strong>2. Is module-level rapid shutdown always safer?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. It isolates voltage down to each PV module, offering the highest protection for firefighters.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"3_Will_string-level_RSD_pass_inspections\"><\/span><strong>3. Will string-level RSD pass inspections?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>In many commercial projects under NEC 2017, yes. Always confirm with your AHJ before finalizing design.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"4_Does_YRO_offer_both_string_and_module-level_solutions\"><\/span><strong>4. Does YRO offer both string and module-level solutions?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. YRO rapid shutdown devices support various PV layouts and compliance requirements.<\/p>","protected":false},"excerpt":{"rendered":"<p>When you design or upgrade a solar project, you need a rapid shutdown solution that meets NEC 2017\/2020 safety codes while keeping installation costs under control. You are likely comparing string level rapid shutdown and module level rapid shutdown to decide which works best for your business. This guide gives you clear, buyer-focused answers. What [&hellip;]<\/p>\n","protected":false},"featured_media":5226,"template":"","meta":{"_acf_changed":false,"footnotes":""},"blog_category":[20],"class_list":["post-5223","blog","type-blog","status-publish","has-post-thumbnail","hentry","blog_category-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/blog\/5223","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/types\/blog"}],"version-history":[{"count":2,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/blog\/5223\/revisions"}],"predecessor-version":[{"id":5227,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/blog\/5223\/revisions\/5227"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/media\/5226"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/media?parent=5223"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/blog_category?post=5223"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}