{"id":4346,"date":"2024-12-13T13:36:48","date_gmt":"2024-12-13T05:36:48","guid":{"rendered":"https:\/\/www.yroele.com\/?post_type=product&#038;p=4346"},"modified":"2026-07-14T15:27:06","modified_gmt":"2026-07-14T07:27:06","slug":"module-rsd-controller-rapid-shutdown-yrsd-p-plc","status":"publish","type":"product","link":"https:\/\/www.yroele.com\/vi\/module-level-firefighter-safety-switch\/yro-rapid-shutdown-module-rsd-mounted-and-rooftop-solar-power-systems-dustproof","title":{"rendered":"M\u00f4-\u0111un t\u1eaft m\u00e1y nhanh YRO H\u1ec7 th\u1ed1ng n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi g\u1eafn tr\u00ean RSD v\u00e0 tr\u00ean m\u00e1i nh\u00e0 Ch\u1ed1ng b\u1ee5i"},"content":{"rendered":"<p><iframe src=\"https:\/\/www.youtube.com\/embed\/88M1JpT2W8k\" width=\"960\" height=\"500\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p>M\u1ee5c 690.12 c\u1ee7a B\u1ed9 lu\u1eadt \u0110i\u1ec7n qu\u1ed1c gia (NEC) n\u0103m 2017 y\u00eau c\u1ea7u h\u1ec7 th\u1ed1ng n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi t\u1eaft nhanh \u1edf c\u1ea5p m\u00f4-\u0111un, t\u1ea5t c\u1ea3 c\u00e1c d\u00e2y d\u1eabn trong ranh gi\u1edbi 1 ft c\u1ee7a d\u00e3y ph\u1ea3i gi\u1ea3m xu\u1ed1ng 80V ho\u1eb7c \u00edt h\u01a1n trong v\u00f2ng 30 gi\u00e2y k\u1ec3 t\u1eeb khi b\u1eaft \u0111\u1ea7u t\u1eaft nhanh.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Tay ngh\u1ec1 v\u00e0 ti\u00eau chu\u1ea9n cao<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" style=\"height: 400px; width: 970px;\" title=\"YRO Rapid Shutdown Module Key Features\" src=\"\/wp-content\/uploads\/otherImg\/1-1008.jpg\" alt=\"Key features of YRO solar rapid shutdown module including IP68 protection, 25A support, UL94-V0 flame retardant, and universal inverter compatibility.\" width=\"970\" height=\"400\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>D\u1eef li\u1ec7u k\u1ef9 thu\u1eadt<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p>Ki\u1ec3u<\/p>\n<\/td>\n<td>\n<p>YRSD-1P<\/p>\n<\/td>\n<td>\n<p>YRSD-2P<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>S\u1ed1 l\u01b0\u1ee3ng \u0111\u1ea7u v\u00e0o PV<\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>S\u1ed1 l\u01b0\u1ee3ng m\u00f4-\u0111un \u0111\u1ec1 xu\u1ea5t<\/p>\n<\/td>\n<td>\n<p>1-2<\/p>\n<\/td>\n<td>\n<p>2-4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u0110i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o t\u1ed1i \u0111a \u0111\u01b0\u1ee3c ph\u00e9p<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>120V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>D\u00f2ng \u0111i\u1ec7n \u0111\u1ea7u v\u00e0o t\u1ed1i \u0111a \u0111\u01b0\u1ee3c ph\u00e9p<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>18A \/ 25A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tu\u1ed5i \u0111i\u1ec7n \u00e1p \u0111\u1ea7u ra t\u1ed1i \u0111a<\/p>\n<\/td>\n<td>\n<p>120V<\/p>\n<\/td>\n<td>\n<p>240V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tu\u1ed5i h\u1ec7 th\u1ed1ng Volt<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1000V \/ 1500V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ki\u1ec3m so\u00e1t tu\u00e2n th\u1ee7<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>C\u00e1p 24VDC + 2x0.8mm2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y\u00eau c\u1ea7u ki\u1ec3m so\u00e1t<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>21,6V ~ 26,4V t\u1ea1i danh ngh\u0129a. 27~36mA\/\u0111\u01a1n v\u1ecb<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nhi\u1ec7t \u0111\u1ed9 ho\u1ea1t \u0111\u1ed9ng xung quanh<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-30\u00b0C \u0111\u1ebfn +60\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Nhi\u1ec7t \u0111\u1ed9 b\u1ea3o v\u1ec7<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>85\u00b0C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>C\u1ea5p IP<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&gt;IP68, NEMA 4X<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>C\u1ea5p \u0111\u1ed9 ch\u1ed1ng ch\u00e1y<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Ch\u1ea5t ch\u1ed1ng ch\u00e1y, UL94-V0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u0110\u1ed9 \u1ea9m<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0%~90%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u0110\u1ea7u n\u1ed1i PV<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tr\u00ecnh k\u1ebft n\u1ed1i (T\u00f9y ch\u1ec9nh)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tu\u1ed5i th\u1ecd thi\u1ebft k\u1ebf<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>25 n\u0103m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>K\u00edch c\u1ee1<\/p>\n<\/td>\n<td>\n<p>155.8*73.7*30.2<\/p>\n<\/td>\n<td>\n<p>155.8*73.7*30.2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>C\u00e2n n\u1eb7ng<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&lt; 200g (Kh\u00f4ng bao g\u1ed3m c\u00e1p)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Chi\u1ec1u d\u00e0i c\u00e1p, \u0111\u1ea7u v\u00e0o PV1+<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Chi\u1ec1u d\u00e0i c\u00e1p, PV1- \u0110\u1ea7u v\u00e0o<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Chi\u1ec1u d\u00e0i c\u00e1p, \u0111\u1ea7u v\u00e0o PV2+<\/p>\n<\/td>\n<td>\n<p>\/<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Chi\u1ec1u d\u00e0i c\u00e1p, PV2- \u0110\u1ea7u v\u00e0o<\/p>\n<\/td>\n<td>\n<p>\/<\/p>\n<\/td>\n<td>\n<p>300mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Chi\u1ec1u d\u00e0i c\u00e1p, c\u00f4ng su\u1ea5t \u0111\u1ea7u ra<\/p>\n<\/td>\n<td>\n<p>1800mm<\/p>\n<\/td>\n<td>\n<p>1800mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Chi\u1ec1u d\u00e0i c\u00e1p, c\u00e1p \u0111i\u1ec1u khi\u1ec3n 24Vdc<\/p>\n<\/td>\n<td>\n<p>1800mm<\/p>\n<\/td>\n<td>\n<p>1800mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tu\u00e2n th\u1ee7 ti\u00eau chu\u1ea9n<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>NEC 2017\/2020 (690,12); UL1741; UL3741; IEC\/EN 62109; IEC\/EN 61000<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>YRSD Lo\u1ea1i PLC c\u1ea5p m\u00f4-\u0111un<\/strong><br \/>\nLo\u1ea1i PLC c\u1ea5p m\u00f4-\u0111un YRSD \u0111\u01b0\u1ee3c thi\u1ebft k\u1ebf \u0111\u1ec3 l\u1eafp \u0111\u1eb7t \u1edf c\u1ea5p \u0111\u1ed9 b\u1ea3ng \u0111i\u1ec1u khi\u1ec3n n\u0103ng l\u01b0\u1ee3ng m\u1eb7t tr\u1eddi v\u00e0 cung c\u1ea5p kh\u1ea3 n\u0103ng t\u1eaft ngu\u1ed3n DC an to\u00e0n \u1edf m\u1ee9c ZERO voltS trong tr\u01b0\u1eddng h\u1ee3p kh\u1ea9n c\u1ea5p. Vi\u1ec7c t\u1eaft m\u00e1y \u0111\u01b0\u1ee3c b\u1eaft \u0111\u1ea7u theo 4 c\u00e1ch \u2013 V\u1eadn h\u00e0nh th\u1ee7 c\u00f4ng, C\u1eaft ngu\u1ed3n cung c\u1ea5p AC ho\u1eb7c B\u1ed9 bi\u1ebfn t\u1ea7n m\u1eb7t tr\u1eddi k\u00edch ho\u1ea1t t\u0103ng nhi\u1ec7t \u0111\u1ed9 nh\u01b0 sau:<\/p>\n<p><img decoding=\"async\" class=\"alignnone\" style=\"height: 520px; width: 970px;\" title=\"4 Ways to Trigger YRO Rapid Shutdown\" src=\"\/wp-content\/uploads\/otherImg\/FaXkStFxk87KhBnE.jpg\" alt=\"Diagram showing four emergency trigger methods for YRO solar rapid shutdown device: Temperature, AC Cut-Off, Manual Switch, and SunSpec Command.\" width=\"970\" height=\"520\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone\" style=\"height: 450px; width: 970px;\" title=\"YRO RSD Safety Approvals &amp; UL Certifications\" src=\"\/wp-content\/uploads\/otherImg\/iW3CimHhdPtPSQcn.jpg\" alt=\"UL1741 PVRSE and UL3741 PVRSS certified YRO rapid shutdown device for the North American solar market.\" width=\"970\" height=\"450\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>YRSD-1P<\/strong><br \/>\nkhi \u0111i\u1ec7n \u00e1p m\u1ea1ch h\u1edf c\u1ee7a t\u1ea5m PV d\u01b0\u1edbi 120V.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" style=\"height: 722px; width: 970px;\" title=\"YRSD-1P System Wiring &amp; NEC Compliance Diagram\" src=\"\/wp-content\/uploads\/otherImg\/jWJTDWzYncENGbbi.jpg\" alt=\"Wiring diagram of YRO YRSD-1P rapid shutdown modules with SunSpec inverter for NEC 2017 and 2020 compliance.\" width=\"970\" height=\"722\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>YRSD-2P<\/strong><br \/>\nkhi \u0111i\u1ec7n \u00e1p m\u1ea1ch h\u1edf c\u1ee7a b\u1ea3ng Pv d\u01b0\u1edbi 120v.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" style=\"height: 611px; width: 970px;\" title=\"YRSD-2P Dual-Panel Wiring Diagram\" src=\"\/wp-content\/uploads\/otherImg\/BCC4xiBMMjjSPjbH.jpg\" alt=\"YRSD-2P system schematic showing odd-number solar panel configuration and SunSpec compatibility.\" width=\"970\" height=\"611\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The 2017 National Electrical Code (NEC) Section 690.12 requires the module-level rapid shutdown of solar systems, all conductors within an array\u2019s 1-ft boundary have to be reduced to 80V or less within 30 seconds of rapid shutdown initiation. &nbsp; High Craftsmanship and Standards &nbsp; Technical Data Type YRSD-1P YRSD-2P Number of PV Inputs 1 2 [&hellip;]<\/p>\n","protected":false},"featured_media":1859,"template":"","meta":{"_acf_changed":false,"footnotes":""},"product_category":[52,54],"product_filter":[],"class_list":["post-4346","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-rapid-shutdown-device","product_category-module-level-firefighter-safety-switch"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/product\/4346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/product\/4346\/revisions"}],"predecessor-version":[{"id":5924,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/product\/4346\/revisions\/5924"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/media\/1859"}],"wp:attachment":[{"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/media?parent=4346"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/product_category?post=4346"},{"taxonomy":"product_filter","embeddable":true,"href":"https:\/\/www.yroele.com\/vi\/wp-json\/wp\/v2\/product_filter?post=4346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}