600/1000/1500V DC SPD Type 1 Type 2 With New Developed Shape
YRSP-D2 Surge protective device, protect against lightning surge voltages in solar system (photovoltaic power supply system).
These units must be installed in parallel on the DC networks to be protected and provide common and different modes protection. Its installed location are recommended at both ends of the DC power supply line (solar panel side and inverter/converter side), especially if the line routing is external and long.
High energy MOVs equipped with specific thermal disconnectors and related failure indicators.
Produktmerkmale
1. Indicator window is obvious (green is OK, red indicates failure)
2. Fully enclosed terminal
3. The shell is made of PC flame retardant material, fire insulation
4. Replaceable module
Technische Daten
| Nennspannung (maximale Dauerspannung) | Uc | 1500Vdc |
| Nennentladestrom (8/20 μs) | In | 20kA |
| Max. Entladestrom (10/350μs) | Imax | 50kA |
| Spannungsschutzniveau | Hoch | ≤3.2kV |
| Ansprechzeit | tA | ≤25ns(L-N) |
| Max. Reservesicherung |
| 125AgL/gG |
| Betriebstemperaturbereich | Di | -40~80℃ |
| Querschnittsfläche |
| 1,5 mm² ~ 25 mm² massiv/35 mm² flexibel |
| Montage an |
| 35 DIN-Schiene |
| Gehäusematerial |
| Lila Modul und hellgrau, UL94-V0 |
| Dimension |
| 4Mods |
| Art der Fernsignalisierungskapazität |
| Schaltkontakt |
| Schaltkapazität |
| Wechselstrom: 250 V/0,5 A; Gleichstrom: 250 V/0,1 A; 125V/0,2A; 75V/0,5A |
| Querschnittsfläche für Fernmeldekontakt |
| Max. 1,5 mm² massiv/flexibel |
| Prüfnormen |
| GB 18802.1; IEC 61643-1 |