The 2017 National Electrical Code (NEC) Section 690.12 requires the module-level rapid shutdown of solar systems, all conductors within an array’s 1-ft boundary have to be reduced to 80V or less within 30 seconds of rapid shutdown initiation.
High Craftsmanship and Standards
Datos técnicos
| Tipo | YRSD-1P | YRSD-2P |
| Number of PV Inputs | 1 | 2 |
| Number of Modules Recommend | 1-2 | 2-4 |
| Maximum Allowed Input Voltage | 120V | |
| Maximum Allowed Input Current | 18A / 25A | |
| Maximum Output Volt age | 120V | 240V |
| System Volt age | 1000V / 1500V | |
| Control Compliance | 24VDC + 2 x 0.8mm2 Cable | |
| Control Requirements | 21.6V~26.4V at nomi. 27~36mA/unit | |
| Temperatura ambiente de funcionamiento | -30°C to +60°C | |
| Protection Temperature | 85°C | |
| IP Level | >IP68, NEMA 4X | |
| Fire-proof Level | Flame retardant, UL94-V0 | |
| Humidity | 0%~90% | |
| PV Connectors | Connector (Customized) | |
| Design Life Span | 25 years | |
| Size | 155.8*73.7*30.2 | 155.8*73.7*30.2 |
| Peso | < 200g (Excluding Cables) | |
| Cable Length, PV1+ Input | 300mm | 300mm |
| Cable Length, PV1- Input | 300mm | 300mm |
| Cable Length, PV2+ Input | / | 300mm |
| Cable Length, PV2- Input | / | 300mm |
| Cable Length, Power Out put | 1800 mm | 1800 mm |
| Cable Length, 24Vdc Control Cable | 1800 mm | 1800 mm |
| andard Comliance | NEC2017/2020 (690.12); UL1741; UL3741; IEC/EN62109; IEC/EN61000 | |
YRSD Modular level PLC type
The YRSD Modular level PLC type is designed to be installed at solar panel level and provides safety shutdown ofthe DC supply to ZERO vOLTS in case of emergency. Shutdown is initiated in 4 ways – Manual Operation, ACSupply Cut-Off or Temperature Rise Trigger sunspec lnverter as follows:
YRSD-1P
when the open-circuit voltage of PV panel is below 120V.
YRSD-2P
when the open-circuit voltage of Pv panel is below 120v.