Module Level Firefighter Safety Switches
● Firefighter Satety Switch for Solar System.
● Over temperature protection.
● Plug and play easy installation.
● IP66 aluminum durable enclosure.
● Emergency button for 100% disconnect.
● Firefighter Satety Switch for Solar System.
● Over temperature protection.
● Plug and play easy installation.
● IP66 aluminum durable enclosure.
● Emergency button for 100% disconnect.
YRO Rapid Shutdown is a DC-breaking device used in photovoltaic system, it can limit the electric range and even DC voltage. To guarantee the safe of firefighters in the process of fire fighting and rescue of facilities installed with photovoltaic power generation system, and has no risk of electric shock.
High Craftsmanship and Standards
Technical Data
Type |
YRSD-1P |
YRSD-2P |
Number of PV Inputs |
1 |
2 |
Number of Modules Recommend |
1-2 |
2-4 |
Maximum Allowed Input Voltage |
120V |
|
Maximum Allowed Input Current |
18A / 25A |
|
Maximum Output Volt age |
120V |
240V |
System Volt age |
1000V / 1500V |
|
Control Compliance |
24VDC + 2 x 0.8mm2 Cable |
|
Control Requirements |
21.6V~26.4V at nomi. 27~36mA/unit |
|
Ambient Operating Temperature |
-30°C to +60°C |
|
Protection Temperature |
85°C |
|
IP Level |
>IP68, NEMA 4X |
|
Fire-proof Level |
Flame retardant, UL94-V0 |
|
Humidity |
0%~90% |
|
PV Connectors |
Connector (Customized) |
|
Design Life Span |
25 years |
|
Size |
155.8*73.7*30.2 |
155.8*73.7*30.2 |
Weight |
< 200g (Excluding Cables) |
|
Cable Length, PV1+ Input |
300mm |
300mm |
Cable Length, PV1- Input |
300mm |
300mm |
Cable Length, PV2+ Input |
/ |
300mm |
Cable Length, PV2- Input |
/ |
300mm |
Cable Length, Power Out put |
1800mm |
1800mm |
Cable Length, 24Vdc Control Cable |
1800mm |
1800mm |
andard Comliance |
NEC2017/2020 (690.12); UL1741; UL3741; IEC/EN62109; IEC/EN61000 |
Summary
The YRO Modular level RSD DC 24V Series Overview is designed to be installed at solar panel level and providessafety shutdown of the DC supply to ZERO VOLTS in case of emergency.Shutdown is initiated in 3 ways -ManualOperation,AC Supply Cut-Off or Temperature Rise Trigger as follows:
YRSD-1P 1-to-1 wiring
Not: For NEC 2017 /2010 compliance PV panels should be <40v for 2-to-1 wiringand > =40v for 1-to-1 wiring (For YRSD -1P)
YRSD-2P 2-to-1 wiring
YRSD-1P/2P Series
Dimension
Technical Specification
Model |
YRSD-CB |
Operating AC Voltage Range |
100V-240V |
Nominal Frequency |
50/60 Hz |
Output Voltage |
24V DC |
Output Current/Power |
2.2A/50W |
24Vdc Control Cable Size |
0.823 mm2/18 AWG |
24Vdc Control Cable Length With Standard Connectors |
20 m / 30 m /100 m |
Spare Terminal Connectors |
Yes |
Maximum YRSD-1P |
60 Units |
Maximum YRSD-2P |
30 Units |
Dimensions (mm) |
250*210*210 |
Lockable |
Optional (IP54) |
Operating Temperature Range |
-30°C~+70°C(50°C No degradation) |
Protection Class |
IP65 |
Mounting |
Wall Mounted |
Maximum Distance (Last RSD to Controller Box) |
200m |
Parallel connection of multiple control boxes
Enhance the reliability and efficiency of your power management system with Yirui's latest innovation, the Quick Switch Auto Transfer Switch. Designed for seamless t...
DC circuit breaker is a protective device for DC circuits, which has the function of quickly cutting off current and preventing overload and short circuit. Circuit b...
In electrical and solar power systems, PV combiner boxes and junction boxes are common terms. Each component plays a crucial role in ensuring the efficiency and safe...